Jussi Tenhunen

  • Phone+358405964623
1990 …2018

Research output per year

If you made any changes in Pure these will be visible here soon.

Research Output

Filter
Article
2013

Fluorescence suppression in Raman spectroscopy using a time-gated CMOS SPAD

Kostamovaara, J., Tenhunen, J., Kögler, M., Nissinen, I., Nissinen, J. & Keränen, P., 6 Dec 2013, In : Optics Express. 21, 25

Research output: Contribution to journalArticleScientificpeer-review

Open Access
74 Citations (Scopus)
2011

FT-IR-cPAS — New Photoacoustic Measurement Technique for Analysis of Hot Gases: A Case Study on VOCs

Hirschmann, C. B., Koivikko, N. S., Raittila, J., Tenhunen, J., Ojala, S., Rahkamaa-Tolonen, K., Marbach, R., Hirschmann, S. & Keiski, R. L., 2011, In : Sensors. 11, 5, p. 5270-5289 20 p.

Research output: Contribution to journalArticleScientificpeer-review

Open Access
8 Citations (Scopus)
2010

Fourier transform infrared photoacoustic multicomponent gas spectroscopy with optical cantilever detection

Hirschmann, C., Uotila, J., Ojala, S., Tenhunen, J. & Keiski, R. L., 2010, In : Applied Spectroscopy. 64, 3, p. 293-297 5 p.

Research output: Contribution to journalArticleScientificpeer-review

12 Citations (Scopus)
2006

Measurement system for monitoring the paper coating process

Paaso, J., Lehtonen, P., Suopajärvi, P., Tenhunen, J., Pajari, H., Koskela, H. & Forsström, U., 2006, In : Professional Papermaking. 1, p. 39-43

Research output: Contribution to journalArticleProfessional

Measurement system for monitoring the paper coating process

Paaso, J., Lehtonen, P., Suopajärvi, P., Tenhunen, J., Pajari, H., Koskela, H. & Forsström, U., 2006, In : Wochenblatt für Papierfabrikation.

Research output: Contribution to journalArticleScientificpeer-review

5 Citations (Scopus)
2003

Analysis of depth profiling data obtained by confocal Raman microspectroscopy

Vyörykkä, J., Paaso, J., Tenhunen, M., Tenhunen, J., Iitti, H., Vuorinen, T. & Stenius, P., 2003, In : Applied Spectroscopy. 57, 9, p. 1123-1128 6 p.

Research output: Contribution to journalArticleScientificpeer-review

25 Citations (Scopus)
2002

Characteristics of immersion sampling technique in confocal Raman depth profiling

Vyörykkä, J., Halttunen, M., Iitti, H., Tenhunen, J., Vuorinen, T. & Stenius, P., 2002, In : Applied Spectroscopy. 56, 6, p. 776-782

Research output: Contribution to journalArticleScientificpeer-review

36 Citations (Scopus)
2001

Characterization of wet massing behavior of silicified microcrystalline cellulose and α-Lactose Monohydrate using near-infrared spectroscopy

Luukkonen, P., Rantanen, J., Mäkelä, K., Räsänen, E., Tenhunen, J. & Yliruusi, J., 2001, In : Pharmaceutical Development and Technology. 6, 1, p. 1-9 9 p.

Research output: Contribution to journalArticleScientificpeer-review

23 Citations (Scopus)

Miniaturization and module integration of an infrared spectrometer

Keränen, K., Karioja, P., Blomberg, M., Tenhunen, J., Rusanen, O. & Kopola, H., 2001, In : Optical Engineering. 40, 10, p. 2308-2314 7 p.

Research output: Contribution to journalArticleScientificpeer-review

3 Citations (Scopus)
2000

In-line moisture measurement during granulation with a four-wavelength near infrared sensor: An evaluation of particle size and binder effects

Rantanen, J., Räsänen, E., Tenhunen, J., Känsäkoski, M., Mannermaa, J-P. & Yliruusi, J., 2000, In : European Journal of Pharmaceutics and Biopharmaceutics. 50, 2, p. 271 - 276 6 p.

Research output: Contribution to journalArticleScientificpeer-review

82 Citations (Scopus)

Miniaturised gas sensor using micromachined fabry-perot interferometer

Saari, H., Mannila, R., Antila, J., Blomberg, M., Rusanen, O., Tenhunen, J., Wolf, L. & Harnisch, B., 2000, In : Preparing for the future: ESA's technology programme quarterly. 10, 3, p. 4-5

Research output: Contribution to journalArticleProfessional

1999

Applicability of FTIR/PAS depth profiling for the study of coated papers

Halttunen, M., Tenhunen, J., Saarinen, T. & Stenius, P., 1999, In : Vibrational Spectroscopy. 19, 2, p. 261-269 9 p.

Research output: Contribution to journalArticleScientificpeer-review

28 Citations (Scopus)
1998

Non-invasive glucose measurement based on selective near infrared absorption: Requirements on instrumentation and spectral range

Tenhunen, J., Kopola, H. & Myllylä, R., 1998, In : Measurement. 24, 3, p. 173-177

Research output: Contribution to journalArticleScientificpeer-review

42 Citations (Scopus)
1996

Determination of the fermentability and extract content of industrial worts by NIR

Sjöholm, K., Tenhunen, J., Tammisola, J., Pietilä, K. & Home, S., 1996, In : Journal of the American Society of Brewing Chemists. 54, 3, p. 135-140 6 p.

Research output: Contribution to journalArticleScientificpeer-review

9 Citations (Scopus)
1994

Determination of fermentable sugars and nitrogenous compounds in wort by near- and mid-infrared spectroscopy

Tenhunen, J., Sjöholm, K., Pietilä, K. & Home, S., 1994, In : Journal of the Institute of Brewing. 100, 1, p. 11-15 5 p.

Research output: Contribution to journalArticleScientificpeer-review

Open Access
21 Citations (Scopus)