No photo of Tuomo Ojanen

Tuomo Ojanen

  • Phone+358405173773
1983 …2020

Research output per year

If you made any changes in Pure these will be visible here soon.

Research Output

Article

Aurinkosähkökennot julkisivukorjauksissa

Ojanen, T. & Heimonen, I., 2000, In : Talotekniikka. 7, p. 44-47

Research output: Contribution to journalArticleProfessional

Aurinkosähkökennot käyttökelpoisia julkisivukorjauksissa

Translated title of the contribution: PV-panels in retro-fitting of building facadesOjanen, T. & Heimonen, I., 2000, In : Rakennuslehti. 11, 10.

Research output: Contribution to journalArticleProfessional

Critical Performance Aspects of Retrofitting Apartment Buildings Using a Multifunctional Façade System

Paiho, S., Ojanen, T., Pinto-Seppä, I. & Paavola, M., 1 Aug 2019, In : Buildings. 9, 8, 184.

Research output: Contribution to journalArticleScientificpeer-review

Open Access
1 Citation (Scopus)

Effect of exfiltration on the hygrothermal behaviour of a residential wall assembly

Ojanen, T. & Kumaran, K., 1996, In : Journal of Thermal Insulation and Building Envelopes. 19, 3, p. 215-227 13 p.

Research output: Contribution to journalArticleScientificpeer-review

10 Citations (Scopus)

Enemmän tehoa paksuista mineraalivillaeristyksistä

Kokko, E. & Ojanen, T., 1996, In : Rakennustaito. 91, 1, p. 16-17

Research output: Contribution to journalArticleProfessional

Heat and mass transfer between indoor air and a permeable and hygroscopic building envelope: Part I - Field measurements

Simonson, C. J., Salonvaara, M. & Ojanen, T., 2004, In : Journal of Thermal Envelope and Building Science. 28, 1, p. 63 - 101 39 p.

Research output: Contribution to journalArticleScientificpeer-review

52 Citations (Scopus)

Heat and mass transfer between indoor air and a permeable and hygroscopic building envelope: Part II - Verification and numerical studies

Simonson, C. J., Salonvaara, M. & Ojanen, T., 2004, In : Journal of Thermal Envelope and Building Science. 28, 2, p. 161 - 185 25 p.

Research output: Contribution to journalArticleScientificpeer-review

36 Citations (Scopus)

Höyrynsulkua tarvitaan päinvastaisista väitteissä huolimatta

Translated title of the contribution: Vapour barrier is necessary despite the opposite argumentsKokko, E. & Ojanen, T., 1999, In : Rakennuslehti. 24

Research output: Contribution to journalArticleProfessional

Ilmatiiveys on tärkeä laadun mittari

Kokko, E. & Ojanen, T., 1999, In : Rakennuslehti. 27, 11.

Research output: Contribution to journalArticleProfessional

Kosteus ja home kuriin

Translated title of the contribution: Better control of moisture and mold growthKokko, E. & Ojanen, T., 1997, In : Rakennustaito. 5, p. 42-43

Research output: Contribution to journalArticleProfessional

Kosteus ja home rakennuksissa on luonnollinen ilmiö

Translated title of the contribution: Moisture and mold growth in buildings is a natural phenomenHukka, A., Kokko, E., Ojanen, T. & Hannu, V., 1997, In : Rakennustaito. 92, 3, p. 26-27

Research output: Contribution to journalArticleProfessional

Kosteuskonvektio on uhka sisäpuolisessa lisäeristämisessä

Kokko, E. & Ojanen, T., 1996, In : Rakennustaito. 91, 2, p. 20-21

Research output: Contribution to journalArticleProfessional

Kuivumiskykyinen rakenne tuulensuojan ulkopuolisella lämmöneristekerroksella

Translated title of the contribution: Improvement of drying capability of a structure with external thermal insulation on windbarrierOjanen, T. & Kokko, E., 2000, In : Rakennuslehti. 3, 9.

Research output: Contribution to journalArticleProfessional

Lasijulkisivujen toimivuus - riskien ja mahdollisuuksien arviointi

Ojanen, T. & Heimonen, I., 2003, In : Lasirakentaja. 13, 4, p. 17-19

Research output: Contribution to journalArticleProfessional

Moisture and bio-deterioration risk of building materials and structures

Viitanen, H., Vinha, J., Salminen, K., Ojanen, T., Peuhkuri, R., Paajanen, L. & Lähdesmäki, K., 2010, In : Journal of Building Physics. 33, 3, p. 201-224

Research output: Contribution to journalArticleScientificpeer-review

161 Citations (Scopus)

Moisture capacity of log houses can improve the indoor climate conditions

Ojanen, T., 2016, In : International Journal for Housing Science and Its Applications. 40, 3, p. 159-169

Research output: Contribution to journalArticleScientificpeer-review

1 Citation (Scopus)

Moisture performance of an airtight, vapor-permeable building envelope in a cold climate

Simonson, C. J., Ojanen, T. & Salonvaara, M., 2005, In : Journal of Thermal Envelope and Building Science. 28, 3, p. 205 - 226 22 p.

Research output: Contribution to journalArticleScientificpeer-review

15 Citations (Scopus)

Moisture performance of mineral wool insulation products in highly insulated structures

Ojanen, T., 1 Jan 2017, In : Energy Procedia. 132, p. 795-800 6 p.

Research output: Contribution to journalArticleScientificpeer-review

Open Access
4 Citations (Scopus)

Mold risk classification based on comparative evaluation of two established growth models

Viitanen, H., Krus, M., Ojanen, T., Eitner, V. & Zirkelbach, D., 2015, In : Energy Procedia. 78, p. 1425-1430

Research output: Contribution to journalArticleScientificpeer-review

Open Access
24 Citations (Scopus)

Övertryck innomhus kan orsaka fuktskador

Translated title of the contribution: Moisture problems are bossible due to indoor overpressure and exfiltrationKokko, E. & Ojanen, T., 1996, In : Bygg & Teknik. 8, p. 60-61

Research output: Contribution to journalArticleProfessional

Rakennusten ilmanpitävyys ja energiatehokkuus

Kauppinen, T., Kovanen, K., Ojanen, T. & Kouhia, I., 2009, In : Rakennuslehti. p. 311-320

Research output: Contribution to journalArticleProfessional

Sisäilman kosteuskuormitusta tasoittavat rakenteet lisäävät asumisviihtyisyyttä

Heimonen, I., Ojanen, T., Salonvaara, M. & Simonson, C., 2001, In : Rakennuslehti. 4, 12.

Research output: Contribution to journalArticleProfessional

Sisäilman kosteuskuormitusta tasoittavat rakenteet lisäävät asumisviihtyisyyttä

Heimonen, I., Ojanen, T., Salonvaara, M. & Simonson, C., 2001, In : Rakennustaito. 2, 18.

Research output: Contribution to journalArticleProfessional

Sisäilman kosteuskuormitusta tasoittavat rakenteet lisäävät asumisviihtyisyyttä

Heimonen, I., Ojanen, T., Salonvaara, M. & Simonson, C., 2001, In : Korjausrakentaminen. 1, p. 30-31

Research output: Contribution to journalArticleProfessional

Sisäilman ylipaine rakenteiden kosteusvaurioiden aiheuttajana

Translated title of the contribution: Indoor overpressure causes moisture damages for structuresOjanen, T. & Kokko, E., 1996, In : Rakennustaito. 4, p. 16-17

Research output: Contribution to journalArticleProfessional

Suljettu aluskatejärjestelmä parantaa katon ilmatiiviyttä ja energiataloutta

Translated title of the contribution: Sealed roof system improves the air tightness and energy performance of a roof structureOjanen, T. & Heimonen, I., 2001, In : Rakennustaito. 9, p. 18-20

Research output: Contribution to journalArticleProfessional

Tasakaton kapillaarinen kuivatus onnistui laboratorioissa

Translated title of the contribution: A capillary flow drained flat roof in succesful laboratoryKokko, E. & Ojanen, T., 1996, In : Rakennustaito. 91, 9, p. 25-26

Research output: Contribution to journalArticleProfessional

The effect of structures on indoor humidity: Possibility to improve comfort and perceived air quality

Simonson, C. J., Salonvaara, M. & Ojanen, T., 2002, In : Indoor Air. 12, 4, p. 243-251

Research output: Contribution to journalArticleScientificpeer-review

123 Citations (Scopus)

Thermal insulation products and applications: Future road maps

Ojanen, T., Pinto-Seppä, I. & Nykänen, E., 2015, In : Energy Procedia. 78, p. 309-314

Research output: Contribution to journalArticleScientificpeer-review

Open Access
7 Citations (Scopus)

VTT tutki EPS-routaeristeen kosteusteknistä toimivuutta

Translated title of the contribution: VTT analysed the moisture performance of EPS frost insulationOjanen, T. & Kokko, E., 1996, In : Rakennustaito. 3, p. 14-15

Research output: Contribution to journalArticleProfessional

Chapter or book article

Cost Effective and Energy Efficient Control of Indoor Humidity in Buildings with Hygroscopic Building Materials and Desiccants in the HVAC System

Fauchoux, M. T., Simonson, C., Torvi, D., Eldeeb, R. & Ojanen, T., 2014, Drying and Wetting of Building Materials and Components. Springer, p. 175-196

Research output: Chapter in Book/Report/Conference proceedingChapter or book articleProfessional

Modeling heat, air and moisture transport through building materials and components

Ojanen, T., Kohonen, R. & Kumaran, M. K., 1994, Moisture Control in Buildings. Trechsel, H. R. (ed.). American Society for Testing and Materials ASTM, p. 18-34 (ASTM Manual Series; No. 18).

Research output: Chapter in Book/Report/Conference proceedingChapter or book articleScientificpeer-review

Conference article

A model for an oil boiler with domestic hot water heat exchanger

Ojanen, T., 1985. 27 p.

Research output: Contribution to conferenceConference articleScientific

Coupled diffusion and convection heat and mass transfer in building structures

Kohonen, R. & Ojanen, T., 1987. 5 p.

Research output: Contribution to conferenceConference articleScientific

Damping of winds pressure and forced convection in mineral fibre wall structures

Kokko, E., Ojanen, T., Karvonen, M-L. & Virtanen, M., 1987. 5 p.

Research output: Contribution to conferenceConference articleScientific

Energiatehokkuusvaatimukset ja rakennusterveys

Ojanen, T. & Airaksinen, M., 2016. 18 p.

Research output: Contribution to conferenceConference articleProfessional

Evaluation of exposure conditions for wooden facades and decking: IRG/WP 09-20408

Viitanen, H., Toratti, T., Peuhkuri, R., Ojanen, T. & Makkonen, L., 2009. 18 p.

Research output: Contribution to conferenceConference articleScientific

Fukt- och värmetekniska egenskaper hos högisolerade konstruktioner: Finska erfarenheter

Kokko, E. & Ojanen, T., 1988, p. 68-89.

Research output: Contribution to conferenceConference articleScientific

Improving the performance of ventilation in large farm buildings in cold climate

Heimonen, I., Heikkinen, J., Kovanen, K., Ojanen, T., Laamanen, J., Lehtinen, J., Alasuutari, S., Louhelainen, K., Mäittälä, J., Kivinen, T. & Jauhiainen, P., 2008.

Research output: Contribution to conferenceConference articleScientific

Indoor air quality in a wooden house

Salonvaara, M., Ojanen, T. & Simonson, C., 2004.

Research output: Contribution to conferenceConference articleScientific

Kosteus-, home- ja laho-ongelmien ja -vaurioiden detektointi ja korjaus: Mitä on opittu viimeisten 30 vuoden aikana?

Viitanen, H., Ojanen, T. & Airaksinen, M., 2013. 6 p.

Research output: Contribution to conferenceConference articleProfessional

Mathematical analysis of mould growth risk in building envelopes

Vinha, J., Salminen, K., Viitanen, H. & Ojanen, T., 2006.

Research output: Contribution to conferenceConference articleScientificpeer-review

Modelling of mould growth in building envelopes: Existing models, discussion on improvement aspects, sensibility analysis

Ojanen, T., Viitanen, H. & Peuhkuri, R., 2007.

Research output: Contribution to conferenceConference articleScientific

Moisture transport coefficient of pine from gamma ray absorption measurements

Kumaran, K., Mitalas, G., Kohonen, R. & Ojanen, T., 1989, p. 179-183.

Research output: Contribution to conferenceConference articleScientificpeer-review

16 Citations (Scopus)

Mould growth in building materials in laboratory and field experiments

Salminen, K., Peuhkuri, R., Lähdesmäki, K., Viitanen, H., Vinha, J., Paajanen, L., Iitti, H., Ojanen, T. & Strander, T., 2007.

Research output: Contribution to conferenceConference articleProfessional

Rakennusmateriaalien homehtumisen mallintaminen

Ojanen, T., Peuhkuri, R. & Viitanen, H., 2009.

Research output: Contribution to conferenceConference articleProfessional

Rakenteiden kosteustekninen toimivuus ja hyvän sisäympäristön varmistaminen

Ojanen, T., 2015.

Research output: Contribution to conferenceConference articleProfessional

Teräsrakenteiden käyttöiän määritys EnnusTeräs -ohjelmalla

Vares, S., Ojanen, T., Pohjanne, P. & Häkkinen, T., 2008. 27 p.

Research output: Contribution to conferenceConference articleScientific

The commissioning procedure of farm building performance in Finland

Kovanen, K., Heimonen, I., Heikkinen, J., Ojanen, T., Laamanen, J., Lehtinen, J., Alasuutari, S., Louhelainen, K., Mäittälä, J., Kivinen, T. & Jauhiainen, P., 2008.

Research output: Contribution to conferenceConference articleScientific

VTT mold model: Equations, parameters, performance criteria

Ojanen, T. & Viitanen, H., 2016.

Research output: Contribution to conferenceConference articleScientific