No photo of Tuomo Ojanen

Tuomo Ojanen

  • Phone+358405173773
1983 …2020

Research output per year

If you made any changes in Pure these will be visible here soon.

Research Output

2000

Moisture performance of buildings with no plastic vapour retarder in cold climates

Simonson, C. & Ojanen, T., 2000, Healthy Buildings 2000: proceedings: Vol. 3: Microbes, Moisture and Building Physics. p. 477-782

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

Numerical simulation of mould growth in timber frame walls

Ojanen, T. & Salonvaara, M., 2000, Healthy Buildings 2000: proceedings: Vol. 3: Microbes, Moisture and Building Physics. p. 335-340

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1999

Höyrynsulkua tarvitaan päinvastaisista väitteissä huolimatta

Translated title of the contribution: Vapour barrier is necessary despite the opposite argumentsKokko, E. & Ojanen, T., 1999, In : Rakennuslehti. 24

Research output: Contribution to journalArticleProfessional

Ilmatiiveys on tärkeä laadun mittari

Kokko, E. & Ojanen, T., 1999, In : Rakennuslehti. 27, 11.

Research output: Contribution to journalArticleProfessional

Puurakenteiden kosteustekninen toiminta

Translated title of the contribution: Moisture physical behaviour of wooden structuresKokko, E., Ojanen, T., Salonvaara, M., Hukka, A. & Viitanen, H., 1999, Espoo: VTT Technical Research Centre of Finland. 161 p. (VTT Tiedotteita - Meddelanden - Research Notes; No. 1991).

Research output: Book/ReportReport

Open Access
1998

Lasikatteinen massiivinen aurinkokerääjäseinä energiaverholla

Translated title of the contribution: Solar collector wall with active curtain systemOjanen, T. & Heimonen, I., 1998, Espoo: VTT Technical Research Centre of Finland. 52 p. (VTT Tiedotteita - Meddelanden - Research Notes; No. 1902).

Research output: Book/ReportReport

1997

Havuvanerirakenteiden kosteusteknisen toiminnan perusteet

Translated title of the contribution: Moisture performance of plywood wall structuresOjanen, T., Kokko, E., Salonvaara, M. & Viitanen, H., 1997, Espoo: VTT Technical Research Centre of Finland. 102 p. (VTT Tiedotteita - Meddelanden - Research Notes; No. 1870).

Research output: Book/ReportReport

3 Citations (Scopus)

Kosteus ja home kuriin

Translated title of the contribution: Better control of moisture and mold growthKokko, E. & Ojanen, T., 1997, In : Rakennustaito. 5, p. 42-43

Research output: Contribution to journalArticleProfessional

Kosteus ja home rakennuksissa on luonnollinen ilmiö

Translated title of the contribution: Moisture and mold growth in buildings is a natural phenomenHukka, A., Kokko, E., Ojanen, T. & Hannu, V., 1997, In : Rakennustaito. 92, 3, p. 26-27

Research output: Contribution to journalArticleProfessional

Uudet vaipparakenteet: Energiansäästö ja kosteustekniikka

Translated title of the contribution: New building envelope structures : energy saving and moisture technologyKokko, E., Ojanen, T. & Salonvaara, M., 1997, Espoo: VTT Technical Research Centre of Finland. 92 p. (VTT Tiedotteita - Meddelanden - Research Notes; No. 1869).

Research output: Book/ReportReport

1996

Effect of exfiltration on the hygrothermal behaviour of a residential wall assembly

Ojanen, T. & Kumaran, K., 1996, In : Journal of Thermal Insulation and Building Envelopes. 19, 3, p. 215-227 13 p.

Research output: Contribution to journalArticleScientificpeer-review

10 Citations (Scopus)

Enemmän tehoa paksuista mineraalivillaeristyksistä

Kokko, E. & Ojanen, T., 1996, In : Rakennustaito. 91, 1, p. 16-17

Research output: Contribution to journalArticleProfessional

EPS-routaeriste: testimenetelmien vertailu

Ojanen, T., 1996. 5 p.

Research output: Contribution to conferenceOther conference contributionProfessional

Kosteuskonvektio on uhka sisäpuolisessa lisäeristämisessä

Kokko, E. & Ojanen, T., 1996, In : Rakennustaito. 91, 2, p. 20-21

Research output: Contribution to journalArticleProfessional

Övertryck innomhus kan orsaka fuktskador

Translated title of the contribution: Moisture problems are bossible due to indoor overpressure and exfiltrationKokko, E. & Ojanen, T., 1996, In : Bygg & Teknik. 8, p. 60-61

Research output: Contribution to journalArticleProfessional

Sisäilman ylipaine rakenteiden kosteusvaurioiden aiheuttajana

Translated title of the contribution: Indoor overpressure causes moisture damages for structuresOjanen, T. & Kokko, E., 1996, In : Rakennustaito. 4, p. 16-17

Research output: Contribution to journalArticleProfessional

Tasakaton kapillaarinen kuivatus onnistui laboratorioissa

Translated title of the contribution: A capillary flow drained flat roof in succesful laboratoryKokko, E. & Ojanen, T., 1996, In : Rakennustaito. 91, 9, p. 25-26

Research output: Contribution to journalArticleProfessional

VTT tutki EPS-routaeristeen kosteusteknistä toimivuutta

Translated title of the contribution: VTT analysed the moisture performance of EPS frost insulationOjanen, T. & Kokko, E., 1996, In : Rakennustaito. 3, p. 14-15

Research output: Contribution to journalArticleProfessional

1995

Wall integrated TI-collector system with natural air convection heat distribution: Analysis and optimization

Ojanen, T., Xu, M. & Aho, I., 1995.

Research output: Contribution to conferenceOther conference contributionScientific

1994

Modeling heat, air and moisture transport through building materials and components

Ojanen, T., Kohonen, R. & Kumaran, M. K., 1994, Moisture Control in Buildings. Trechsel, H. R. (ed.). American Society for Testing and Materials ASTM, p. 18-34 (ASTM Manual Series; No. 18).

Research output: Chapter in Book/Report/Conference proceedingChapter or book articleScientificpeer-review

1993

Tuulensuojan toimintaperusteet

Ojanen, T., Kokko, E. & Pallari, M-L., 1993, Espoo: VTT Technical Research Centre of Finland. 155 p. (VTT Tiedotteita - Meddelanden - Research Notes; No. 1478).

Research output: Book/ReportReport

Open Access

Vedottomien ulkoilmaventtiilien kehittämisperusteet

Translated title of the contribution: Development of draughtless outdoor air inletsHeikkinen, J., Kovanen, K., Ojanen, T., Pallari, M-L., Piira, K. & Siitonen, V., 1993, Espoo: VTT Technical Research Centre of Finland. 112 p. (VTT Tiedotteita - Meddelanden - Research Notes; No. 1468).

Research output: Book/ReportReport

Open Access
1992

Integroidut kevyet rakenteet

Nieminen, J., Kouhia, I., Ojanen, T., Piira, K. & Salonvaara, M., 1992, Espoo: VTT Technical Research Centre of Finland. 60 p. (ETRR-tutkimusohjelma. Raportti; No. 10).

Research output: Book/ReportReport

Numerical simulation of structures with transparent thermal insulations and phase change materials

Ojanen, T. & Salonvaara, M., 1992, Espoo: VTT Technical Research Centre of Finland. 80 p. (ETRR Report, Vol. 14).

Research output: Book/ReportReport

Transparent insulations, cold-region applications

Kouhia, I., Nieminen, J., Rautiainen, L., Ojanen, T. & Salonvaara, M., 1992, VTT Technical Research Centre of Finland. 32 p. (ETRR Report; No. 16).

Research output: Book/ReportReport

Valoaläpäisevät lämmöneristeet: Kylmän ilmaston sovellutuksia

Kouhia, I., Nieminen, J., Rautiainen, L., Ojanen, T. & Salonvaara, M., 1992, VTT Technical Research Centre of Finland. 34 p. (ETRR-tutkimusohjelma. Raportti; No. 17).

Research output: Book/ReportReport

1991

Numerically analysed applications of transparent insulations

Ojanen, T., 1991, Fourth International Workshop on Transparent Insulation Technology: Proceedings. Jesch, L. F. (ed.). Birmingham, p. 111-114

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

Simulation of TIM and PCM applications in building envelopes

Salonvaara, M., Ojanen, T. & Kohonen, R., 1991, IEA-Workshop on Thermal Energy Storage and Low Energy Buildings: Workshop Proceedings. Schölkopf, W. (ed.). Tutzing, p. 125-132

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1990

Convection and moisture driven heat transfer

Ojanen, T. & Kohonen, R., 1990, International CIB W67 Symposium on Energy, Moisture and Climate in Buildings. Rotterdam, 6 p. (CIB Publication, Vol. 121).

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientific

Puun sähköiset mittausmenetelmät. Osa 4. Puun kosteudenjohtavuuden ja kapillaarisuuden määritys gammasäteilylaitteiston avulla

Ojanen, T., 1990, Espoo. 70 p. (Valtion teknillinen tutkimuskeskus. Tiedotteita; No. 1189).

Research output: Book/ReportReport

1989

Hygrothermal influence of air convection in wall structures

Ojanen, T. & Kohonen, R., 1989, Thermal Performance of the Exterior of Buildings IV: Proceedings of the ASHRAE/DOE/BTECC/CIBSE conference. Atlanta: ASHRAE, p. 234-249

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientific

Ilmavirtausten vaikutus rakenteiden lämpö- ja kosteustekniseen toimintaan

Ojanen, T. & Kohonen, R., 1989, Espoo: VTT Technical Research Centre of Finland. 110 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 590).

Research output: Book/ReportReport

Kosteuden siirtyminen rakenteissa: Rakennusaineiden kosteustekniset ominaisuudet

Saarimaa, J., Nieminen, J., Rautiainen, L., Ojanen, T. & Kohonen, R., 1989, Espoo: VTT Technical Research Centre of Finland. 102 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 644).

Research output: Book/ReportReport

Kosteuden siirtyminen rakenteissa: Laskentamenetelmät

Ojanen, T., Salonvaara, M., Kohonen, R. & Nieminen, J., 1989, Espoo: VTT Technical Research Centre of Finland. 106 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 595).

Research output: Book/ReportReport

2 Citations (Scopus)

Moisture transport coefficient of pine from gamma ray absorption measurements

Kumaran, K., Mitalas, G., Kohonen, R. & Ojanen, T., 1989, p. 179-183.

Research output: Contribution to conferenceConference articleScientificpeer-review

16 Citations (Scopus)
1988

Fukt- och värmetekniska egenskaper hos högisolerade konstruktioner: Finska erfarenheter

Kokko, E. & Ojanen, T., 1988, p. 68-89.

Research output: Contribution to conferenceConference articleScientific

1987

Coupled diffusion and convection heat and mass transfer in building structures

Kohonen, R. & Ojanen, T., 1987. 5 p.

Research output: Contribution to conferenceConference articleScientific

Damping of winds pressure and forced convection in mineral fibre wall structures

Kokko, E., Ojanen, T., Karvonen, M-L. & Virtanen, M., 1987. 5 p.

Research output: Contribution to conferenceConference articleScientific

Non-steady-state coupled diffusion and convection heat and mass transfer in porous media

Kohonen, R. & Ojanen, T., 1987, 5th International Conference on Numerical Methods in Thermal Problems. Vol. 1. p. 705-716

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

Thermal coupling of leakage flows and heating load of buildings

Kohonen, R., Ojanen, T. & Virtanen, M., 1987, 8th AIVC Conference: Ventilation technology Research and application. Air Infiltration & Ventilation Centre AIVC, p. 10.1-10.21

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1986

Mineraalivillaeristyksen ilmavirtaukset ja tuulensuojaus

Kohonen, R., Kokko, E., Mähönen, T. & Ojanen, T., 1986, Espoo: VTT Technical Research Centre of Finland. 119 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 431).

Research output: Book/ReportReport

Thermal performance of wall structures in relation to air and moisture flow

Kohonen, R., Ojanen, T. & Virtanen, M., 1986, Advancing Building Technology: Proceedings of the 10th Triennial Congress of the International Council for Building Research, Studies and Documentation. 11 p.

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1985

A model for an oil boiler with domestic hot water heat exchanger

Ojanen, T., 1985. 27 p.

Research output: Contribution to conferenceConference articleScientific

Coupled convection and conduction in two-dimensional building structures

Kohonen, R. & Ojanen, T., 1985, Proceedings of the 4th International Conference on Numerical Methods in Thermal Problems. Lewis, R. & Morgan, K. (eds.). Swansea, 11 p.

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

Höyrynsuluton puurunkoinen seinärakenne ENSO-koetalossa

Kohonen, R., Määttä, J., Nieminen, J., Ojanen, T. & Saarimaa, J., 1985, Espoo: VTT Technical Research Centre of Finland. 82 p. (Valtion teknillinen tutkimuskeskus. Tiedotteita; No. 441).

Research output: Book/ReportReport

Thermal effects of air flows in building structures

Kohonen, R., Kokko, E., Ojanen, T. & Virtanen, M., 1985, Espoo: VTT Technical Research Centre of Finland. 82 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 367).

Research output: Book/ReportReport

1983

Rakennusmateriaalien vesihöyryn- ja kosteudenjohtavuuden määritysmenetelmä

Kohonen, R. & Ojanen, T., 1983, Espoo: VTT Technical Research Centre of Finland. 78 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 188).

Research output: Book/ReportReport