A flexible microrobotic platform for handling microscale specimens of fibrous materials for microscopic studies

P. Saketi, M. von Essen, M. Mikczinski, Sabine Heinemann, S. Fatikow, P. Kallio

Research output: Contribution to journalArticleScientificpeer-review

19 Citations (Scopus)

Abstract

One of the most challenging issues faced in handling specimens for microscopy, is avoiding artefacts and structural changes in the samples caused by human errors. In addition, specimen handling is a laborious and time‐consuming task and requires skilful and experienced personnel. This paper introduces a flexible microrobotic platform for the handling of microscale specimens of fibrous materials for various microscopic studies such as scanning electron microscopy and nanotomography. The platform is capable of handling various fibres with diameters ranging from 10 to 1000 μm and lengths of 100 μm–15 mm, and mounting them on different types of specimen holders without damaging them. This tele‐operated microrobotic platform minimizes human interaction with the samples, which is one of the main sources contributory to introducing artefacts into the specimens. The platform also grants a higher throughput and an improved success rate of specimen handling, when compared to the manual processes. The operator does not need extensive experience of microscale manipulation and only a short training period is sufficient to operate the platform. The requirement of easy configurability for various samples and sample holders is typical in the research and development of materials in this field. Therefore, one of the main criteria for the design of the microrobotic platform was the ability to adapt the platform to different specimen handling methods required for microscopic studies. To demonstrate this, three experiments are carried out using the microrobotic platform. In the first experiment, individual paper fibres are mounted successfully on scanning electron microscopy specimen holders for the in situ scanning electron microscopy diagonal compression test of paper fibres. The performance of the microrobotic platform is compared with a skilled laboratory worker performing the same experiment. In the second experiment, a strand of human hair and an individual paper fibre bond are mounted on a specimen holder for nanotomography studies. In the third experiment, individual paper fibre bonds with controlled crossing and vertical angles are made using the microrobotic platform. If an industrial application requires less flexibility but a higher speed when handling one type of sample to a specific holder, then the platform can be automated in the future.
Original languageEnglish
Pages (from-to)163-171
JournalJournal of Microscopy
Volume248
Issue number2
DOIs
Publication statusPublished - 2012
MoE publication typeA1 Journal article-refereed

Fingerprint

Specimen Handling
Electron Scanning Microscopy
Artifacts
Organized Financing
Hair
Microscopy
Research

Keywords

  • Fibrous material
  • microrobotic
  • microscale samples
  • microscopy
  • sample handling
  • specimen handling

Cite this

Saketi, P. ; von Essen, M. ; Mikczinski, M. ; Heinemann, Sabine ; Fatikow, S. ; Kallio, P. / A flexible microrobotic platform for handling microscale specimens of fibrous materials for microscopic studies. In: Journal of Microscopy. 2012 ; Vol. 248, No. 2. pp. 163-171.
@article{20eaff8377f04490bc7eccf376fa2c98,
title = "A flexible microrobotic platform for handling microscale specimens of fibrous materials for microscopic studies",
abstract = "One of the most challenging issues faced in handling specimens for microscopy, is avoiding artefacts and structural changes in the samples caused by human errors. In addition, specimen handling is a laborious and time‐consuming task and requires skilful and experienced personnel. This paper introduces a flexible microrobotic platform for the handling of microscale specimens of fibrous materials for various microscopic studies such as scanning electron microscopy and nanotomography. The platform is capable of handling various fibres with diameters ranging from 10 to 1000 μm and lengths of 100 μm–15 mm, and mounting them on different types of specimen holders without damaging them. This tele‐operated microrobotic platform minimizes human interaction with the samples, which is one of the main sources contributory to introducing artefacts into the specimens. The platform also grants a higher throughput and an improved success rate of specimen handling, when compared to the manual processes. The operator does not need extensive experience of microscale manipulation and only a short training period is sufficient to operate the platform. The requirement of easy configurability for various samples and sample holders is typical in the research and development of materials in this field. Therefore, one of the main criteria for the design of the microrobotic platform was the ability to adapt the platform to different specimen handling methods required for microscopic studies. To demonstrate this, three experiments are carried out using the microrobotic platform. In the first experiment, individual paper fibres are mounted successfully on scanning electron microscopy specimen holders for the in situ scanning electron microscopy diagonal compression test of paper fibres. The performance of the microrobotic platform is compared with a skilled laboratory worker performing the same experiment. In the second experiment, a strand of human hair and an individual paper fibre bond are mounted on a specimen holder for nanotomography studies. In the third experiment, individual paper fibre bonds with controlled crossing and vertical angles are made using the microrobotic platform. If an industrial application requires less flexibility but a higher speed when handling one type of sample to a specific holder, then the platform can be automated in the future.",
keywords = "Fibrous material, microrobotic, microscale samples, microscopy, sample handling, specimen handling",
author = "P. Saketi and {von Essen}, M. and M. Mikczinski and Sabine Heinemann and S. Fatikow and P. Kallio",
year = "2012",
doi = "10.1111/j.1365-2818.2012.03660.x",
language = "English",
volume = "248",
pages = "163--171",
journal = "Journal of Microscopy",
issn = "0022-2720",
number = "2",

}

A flexible microrobotic platform for handling microscale specimens of fibrous materials for microscopic studies. / Saketi, P.; von Essen, M.; Mikczinski, M.; Heinemann, Sabine; Fatikow, S.; Kallio, P.

In: Journal of Microscopy, Vol. 248, No. 2, 2012, p. 163-171.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - A flexible microrobotic platform for handling microscale specimens of fibrous materials for microscopic studies

AU - Saketi, P.

AU - von Essen, M.

AU - Mikczinski, M.

AU - Heinemann, Sabine

AU - Fatikow, S.

AU - Kallio, P.

PY - 2012

Y1 - 2012

N2 - One of the most challenging issues faced in handling specimens for microscopy, is avoiding artefacts and structural changes in the samples caused by human errors. In addition, specimen handling is a laborious and time‐consuming task and requires skilful and experienced personnel. This paper introduces a flexible microrobotic platform for the handling of microscale specimens of fibrous materials for various microscopic studies such as scanning electron microscopy and nanotomography. The platform is capable of handling various fibres with diameters ranging from 10 to 1000 μm and lengths of 100 μm–15 mm, and mounting them on different types of specimen holders without damaging them. This tele‐operated microrobotic platform minimizes human interaction with the samples, which is one of the main sources contributory to introducing artefacts into the specimens. The platform also grants a higher throughput and an improved success rate of specimen handling, when compared to the manual processes. The operator does not need extensive experience of microscale manipulation and only a short training period is sufficient to operate the platform. The requirement of easy configurability for various samples and sample holders is typical in the research and development of materials in this field. Therefore, one of the main criteria for the design of the microrobotic platform was the ability to adapt the platform to different specimen handling methods required for microscopic studies. To demonstrate this, three experiments are carried out using the microrobotic platform. In the first experiment, individual paper fibres are mounted successfully on scanning electron microscopy specimen holders for the in situ scanning electron microscopy diagonal compression test of paper fibres. The performance of the microrobotic platform is compared with a skilled laboratory worker performing the same experiment. In the second experiment, a strand of human hair and an individual paper fibre bond are mounted on a specimen holder for nanotomography studies. In the third experiment, individual paper fibre bonds with controlled crossing and vertical angles are made using the microrobotic platform. If an industrial application requires less flexibility but a higher speed when handling one type of sample to a specific holder, then the platform can be automated in the future.

AB - One of the most challenging issues faced in handling specimens for microscopy, is avoiding artefacts and structural changes in the samples caused by human errors. In addition, specimen handling is a laborious and time‐consuming task and requires skilful and experienced personnel. This paper introduces a flexible microrobotic platform for the handling of microscale specimens of fibrous materials for various microscopic studies such as scanning electron microscopy and nanotomography. The platform is capable of handling various fibres with diameters ranging from 10 to 1000 μm and lengths of 100 μm–15 mm, and mounting them on different types of specimen holders without damaging them. This tele‐operated microrobotic platform minimizes human interaction with the samples, which is one of the main sources contributory to introducing artefacts into the specimens. The platform also grants a higher throughput and an improved success rate of specimen handling, when compared to the manual processes. The operator does not need extensive experience of microscale manipulation and only a short training period is sufficient to operate the platform. The requirement of easy configurability for various samples and sample holders is typical in the research and development of materials in this field. Therefore, one of the main criteria for the design of the microrobotic platform was the ability to adapt the platform to different specimen handling methods required for microscopic studies. To demonstrate this, three experiments are carried out using the microrobotic platform. In the first experiment, individual paper fibres are mounted successfully on scanning electron microscopy specimen holders for the in situ scanning electron microscopy diagonal compression test of paper fibres. The performance of the microrobotic platform is compared with a skilled laboratory worker performing the same experiment. In the second experiment, a strand of human hair and an individual paper fibre bond are mounted on a specimen holder for nanotomography studies. In the third experiment, individual paper fibre bonds with controlled crossing and vertical angles are made using the microrobotic platform. If an industrial application requires less flexibility but a higher speed when handling one type of sample to a specific holder, then the platform can be automated in the future.

KW - Fibrous material

KW - microrobotic

KW - microscale samples

KW - microscopy

KW - sample handling

KW - specimen handling

U2 - 10.1111/j.1365-2818.2012.03660.x

DO - 10.1111/j.1365-2818.2012.03660.x

M3 - Article

VL - 248

SP - 163

EP - 171

JO - Journal of Microscopy

JF - Journal of Microscopy

SN - 0022-2720

IS - 2