Skip to main navigation Skip to search Skip to main content

A Novel L1-and-L2-Norm-Integrated Parameter Identification Model for Robot Calibration

  • Zhibin Li
  • , Pengwei Hu*
  • , Xun Deng
  • , Lun Hu
  • , Shuai Li
  • , Xin Luo
  • *Corresponding author for this work
    • Xinjiang Technical Institute of Physics and Chemistry
    • Chengdu University of Information Technology
    • Sichuan University of Arts and Science
    • University of Oulu
    • Southwest University

    Research output: Contribution to journal › Article › Scientific › peer-review

    Abstract

    Robots promote the social development by enhancing production efficiency, reducing labor costs, and improving service quality. Meanwhile, their application fields such as healthcare, transportation, and education can drive technological advancement and innovation, thus fostering economic growth and improving our quality of life. However, due to mechanical wear from prolonged operation, the robot absolute positioning error can reach several millimeters, thus it is impossible for them to perform precise tasks. To address this intractable problem, this study innovatively proposes a robot calibration method (FPSA) combining the search algorithm based on proportion integration differentiation (PID) controller and fuzzy strategy for adjusting hyperparameter, its novelties include: 1) designing a novel L1-and-L2-norm-integrated parameter identification model, then search algorithm [PID search algorithm (PSA)] based on PID controller is adopted to solve this model, which achieves the accurate identification of robot kinematic errors; and 2) developing an efficient fuzzy strategy for adjusting hyperparameter to achieve hyperparameter adaptation in the robot parameter identification model, thereby effectively enhancing the calibration computation efficiency and accuracy. Moreover, we conduct extensive calibration experiments on an HSR JR680 robot. These experimental results demonstrate that compared with other advanced calibration algorithms, the maximum error of the proposed FPSA calibration method is 9.57% higher than that of the most accurate identification model solved by PSA algorithm, which has single L2 norm regularization and objective function. Therefore, this research provides excellent calibration service for a robot, thus contributing to the prosperous development of application fields such as industrial manufacturing and smart agriculture.

    Original languageEnglish
    Pages (from-to)10352-10363
    Number of pages12
    JournalIEEE Transactions on Industrial Electronics
    Volume73
    Issue number7
    DOIs
    Publication statusPublished - 2026
    MoE publication typeA1 Journal article-refereed

    Funding

    This work was supported in part by the National Funded Postdoctoral Research Program under Grant GZC20241900, in part by the Natural Science Foundation Program of Xinjiang Uygur Autonomous Region under Grant 2024D01A141, in part by the Tianchi Talents Program of Xinjiang Uygur Autonomous Region, and in part by the open project of Dazhou Key Laboratory of Government Data Security under Grant ZSAQ202502.

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 8 - Decent Work and Economic Growth
      SDG 8 Decent Work and Economic Growth
    2. SDG 9 - Industry, Innovation, and Infrastructure
      SDG 9 Industry, Innovation, and Infrastructure

    Keywords

    • Fuzzy strategy for adjusting hyperparameter
    • parameter identification model
    • production efficiency
    • proportion integration differentiation (PID) controller
    • robot calibration

    Fingerprint

    Dive into the research topics of 'A Novel L1-and-L2-Norm-Integrated Parameter Identification Model for Robot Calibration'. Together they form a unique fingerprint.

    Cite this