A run-in test series of a smoke test room

Tests according to the proposal prEN 54-9

Antti Ahonen, Pauli Sysiö

Research output: Book/ReportReportProfessional

Abstract

The results of a run-in test series on a fire sensitivity test room according to the European Standard proposal prEN-54-9 are reported. The construction and the properties of the test room, in addition to the measuring instruments and principles are briefly described. All the test fires could be carried out to the prEN 54-9 specifications, although some difficulties with the smouldering fires were observed. The difficulties are mainly due to insufficient definitions in the standard proposal.
Original languageEnglish
Place of PublicationEspoo
PublisherVTT Technical Research Centre of Finland
Number of pages36
ISBN (Print)951-38-1645-1
Publication statusPublished - 1983
MoE publication typeD4 Published development or research report or study

Publication series

NameTutkimuksia / Valtion teknillinen tutkimuskeskus
PublisherVTT
Volume139

Fingerprint

Smoke
Fires
Specifications

Cite this

Ahonen, A., & Sysiö, P. (1983). A run-in test series of a smoke test room: Tests according to the proposal prEN 54-9. Espoo: VTT Technical Research Centre of Finland. Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports, No. 139
Ahonen, Antti ; Sysiö, Pauli. / A run-in test series of a smoke test room : Tests according to the proposal prEN 54-9. Espoo : VTT Technical Research Centre of Finland, 1983. 36 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 139).
@book{6a11b938371644a1a573688af26fca32,
title = "A run-in test series of a smoke test room: Tests according to the proposal prEN 54-9",
abstract = "The results of a run-in test series on a fire sensitivity test room according to the European Standard proposal prEN-54-9 are reported. The construction and the properties of the test room, in addition to the measuring instruments and principles are briefly described. All the test fires could be carried out to the prEN 54-9 specifications, although some difficulties with the smouldering fires were observed. The difficulties are mainly due to insufficient definitions in the standard proposal.",
author = "Antti Ahonen and Pauli Sysi{\"o}",
year = "1983",
language = "English",
isbn = "951-38-1645-1",
series = "Tutkimuksia / Valtion teknillinen tutkimuskeskus",
publisher = "VTT Technical Research Centre of Finland",
address = "Finland",

}

Ahonen, A & Sysiö, P 1983, A run-in test series of a smoke test room: Tests according to the proposal prEN 54-9. Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports, no. 139, VTT Technical Research Centre of Finland, Espoo.

A run-in test series of a smoke test room : Tests according to the proposal prEN 54-9. / Ahonen, Antti; Sysiö, Pauli.

Espoo : VTT Technical Research Centre of Finland, 1983. 36 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 139).

Research output: Book/ReportReportProfessional

TY - BOOK

T1 - A run-in test series of a smoke test room

T2 - Tests according to the proposal prEN 54-9

AU - Ahonen, Antti

AU - Sysiö, Pauli

PY - 1983

Y1 - 1983

N2 - The results of a run-in test series on a fire sensitivity test room according to the European Standard proposal prEN-54-9 are reported. The construction and the properties of the test room, in addition to the measuring instruments and principles are briefly described. All the test fires could be carried out to the prEN 54-9 specifications, although some difficulties with the smouldering fires were observed. The difficulties are mainly due to insufficient definitions in the standard proposal.

AB - The results of a run-in test series on a fire sensitivity test room according to the European Standard proposal prEN-54-9 are reported. The construction and the properties of the test room, in addition to the measuring instruments and principles are briefly described. All the test fires could be carried out to the prEN 54-9 specifications, although some difficulties with the smouldering fires were observed. The difficulties are mainly due to insufficient definitions in the standard proposal.

M3 - Report

SN - 951-38-1645-1

T3 - Tutkimuksia / Valtion teknillinen tutkimuskeskus

BT - A run-in test series of a smoke test room

PB - VTT Technical Research Centre of Finland

CY - Espoo

ER -

Ahonen A, Sysiö P. A run-in test series of a smoke test room: Tests according to the proposal prEN 54-9. Espoo: VTT Technical Research Centre of Finland, 1983. 36 p. (Valtion teknillinen tutkimuskeskus. Tutkimuksia - Research Reports; No. 139).