A toolkit for epithermal neutron beam characterisation in BNCT

Iiro Auterinen (Corresponding Author), Tom Seren, Jouni Uusi-Simola, Antti Kosunen, Sauli Savolainen

Research output: Contribution to journalArticleScientificpeer-review

6 Citations (Scopus)

Abstract

Methods for dosimetry of epithermal neutron beams used in boron neutron capture therapy (BNCT) have been developed and utilised within the Finnish BNCT project as well as within a European project for a code of practise for the dosimetry of BNCT. One outcome has been a travelling toolkit for BNCT dosimetry. It consists of activation detectors and ionisation chambers. The free-beam neutron spectrum is measured with a set of activation foils of different isotopes irradiated both in a Cd-capsule and without it. Neutron flux (thermal and epithermal) distribution in phantoms is measured using activation of Mn and Au foils, and Cu wire. Ionisation chamber (IC) measurements are performed both in-free-beam and in-phantom for determination of the neutron and gamma dose components. This toolkit has also been used at other BNCT facilities in Europe, the USA, Argentina and Japan.
Original languageEnglish
Pages (from-to)587 - 593
Number of pages7
JournalRadiation Protection Dosimetry
Volume110
Issue number1-4
DOIs
Publication statusPublished - 2004
MoE publication typeA1 Journal article-refereed

Fingerprint

Boron Neutron Capture Therapy
neutron beams
Neutrons
therapy
boron
neutrons
dosimeters
activation
ionization chambers
foils
Argentina
Isotopes
neutron spectra
Capsules
capsules
flux (rate)
Japan
Hot Temperature
isotopes
wire

Keywords

  • Boron Neutron Capture Therapy
  • dosimetry
  • Neutron Dosimetry
  • toolkits

Cite this

Auterinen, I., Seren, T., Uusi-Simola, J., Kosunen, A., & Savolainen, S. (2004). A toolkit for epithermal neutron beam characterisation in BNCT. Radiation Protection Dosimetry, 110(1-4), 587 - 593. https://doi.org/10.1093/rpd/nch151
Auterinen, Iiro ; Seren, Tom ; Uusi-Simola, Jouni ; Kosunen, Antti ; Savolainen, Sauli. / A toolkit for epithermal neutron beam characterisation in BNCT. In: Radiation Protection Dosimetry. 2004 ; Vol. 110, No. 1-4. pp. 587 - 593.
@article{d7f5febbe9c74930b42078f9d7bd46d6,
title = "A toolkit for epithermal neutron beam characterisation in BNCT",
abstract = "Methods for dosimetry of epithermal neutron beams used in boron neutron capture therapy (BNCT) have been developed and utilised within the Finnish BNCT project as well as within a European project for a code of practise for the dosimetry of BNCT. One outcome has been a travelling toolkit for BNCT dosimetry. It consists of activation detectors and ionisation chambers. The free-beam neutron spectrum is measured with a set of activation foils of different isotopes irradiated both in a Cd-capsule and without it. Neutron flux (thermal and epithermal) distribution in phantoms is measured using activation of Mn and Au foils, and Cu wire. Ionisation chamber (IC) measurements are performed both in-free-beam and in-phantom for determination of the neutron and gamma dose components. This toolkit has also been used at other BNCT facilities in Europe, the USA, Argentina and Japan.",
keywords = "Boron Neutron Capture Therapy, dosimetry, Neutron Dosimetry, toolkits",
author = "Iiro Auterinen and Tom Seren and Jouni Uusi-Simola and Antti Kosunen and Sauli Savolainen",
year = "2004",
doi = "10.1093/rpd/nch151",
language = "English",
volume = "110",
pages = "587 -- 593",
journal = "Radiation Protection Dosimetry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1-4",

}

Auterinen, I, Seren, T, Uusi-Simola, J, Kosunen, A & Savolainen, S 2004, 'A toolkit for epithermal neutron beam characterisation in BNCT', Radiation Protection Dosimetry, vol. 110, no. 1-4, pp. 587 - 593. https://doi.org/10.1093/rpd/nch151

A toolkit for epithermal neutron beam characterisation in BNCT. / Auterinen, Iiro (Corresponding Author); Seren, Tom; Uusi-Simola, Jouni; Kosunen, Antti; Savolainen, Sauli.

In: Radiation Protection Dosimetry, Vol. 110, No. 1-4, 2004, p. 587 - 593.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - A toolkit for epithermal neutron beam characterisation in BNCT

AU - Auterinen, Iiro

AU - Seren, Tom

AU - Uusi-Simola, Jouni

AU - Kosunen, Antti

AU - Savolainen, Sauli

PY - 2004

Y1 - 2004

N2 - Methods for dosimetry of epithermal neutron beams used in boron neutron capture therapy (BNCT) have been developed and utilised within the Finnish BNCT project as well as within a European project for a code of practise for the dosimetry of BNCT. One outcome has been a travelling toolkit for BNCT dosimetry. It consists of activation detectors and ionisation chambers. The free-beam neutron spectrum is measured with a set of activation foils of different isotopes irradiated both in a Cd-capsule and without it. Neutron flux (thermal and epithermal) distribution in phantoms is measured using activation of Mn and Au foils, and Cu wire. Ionisation chamber (IC) measurements are performed both in-free-beam and in-phantom for determination of the neutron and gamma dose components. This toolkit has also been used at other BNCT facilities in Europe, the USA, Argentina and Japan.

AB - Methods for dosimetry of epithermal neutron beams used in boron neutron capture therapy (BNCT) have been developed and utilised within the Finnish BNCT project as well as within a European project for a code of practise for the dosimetry of BNCT. One outcome has been a travelling toolkit for BNCT dosimetry. It consists of activation detectors and ionisation chambers. The free-beam neutron spectrum is measured with a set of activation foils of different isotopes irradiated both in a Cd-capsule and without it. Neutron flux (thermal and epithermal) distribution in phantoms is measured using activation of Mn and Au foils, and Cu wire. Ionisation chamber (IC) measurements are performed both in-free-beam and in-phantom for determination of the neutron and gamma dose components. This toolkit has also been used at other BNCT facilities in Europe, the USA, Argentina and Japan.

KW - Boron Neutron Capture Therapy

KW - dosimetry

KW - Neutron Dosimetry

KW - toolkits

U2 - 10.1093/rpd/nch151

DO - 10.1093/rpd/nch151

M3 - Article

VL - 110

SP - 587

EP - 593

JO - Radiation Protection Dosimetry

JF - Radiation Protection Dosimetry

SN - 0144-8420

IS - 1-4