Adding power quality monitoring into a smart kWh-meter

Pekka Koponen, Reino Seesvuori, R. Böstman

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1 Citation (Scopus)

Abstract

In this paper, the authors describe a method that gives some power quality quantities, like total voltage distortion and voltage unbalance, from relatively sparsely sampled measurements. It is based on an adaptive state observer for the voltage phasors. Requirements for power quality monitoring in power distribution are listed and the results of the laboratory and field tests of new power quality monitoring kWh-meters summarised together with field use experience. Finally, they discuss the needs and possibilities for future development.
Original languageEnglish
Title of host publicationEighth International Conference on Metering and Tariffs for Energy Supply
PublisherInstitution of Engineering and Technology IET
Pages6-10
ISBN (Print)0-85296-660-1
DOIs
Publication statusPublished - 1996
MoE publication typeA4 Article in a conference publication
Event8th International Conference on Meeting and Tariffs for Electricity Supply, IEE MATES'96 - Brighton, United Kingdom
Duration: 3 Jul 19965 Jul 1996

Publication series

SeriesIEE Conference Publication
ISSN0537-9989

Conference

Conference8th International Conference on Meeting and Tariffs for Electricity Supply, IEE MATES'96
Abbreviated titleIEE MATES'96
CountryUnited Kingdom
CityBrighton
Period3/07/965/07/96

Fingerprint Dive into the research topics of 'Adding power quality monitoring into a smart kWh-meter'. Together they form a unique fingerprint.

  • Cite this

    Koponen, P., Seesvuori, R., & Böstman, R. (1996). Adding power quality monitoring into a smart kWh-meter. In Eighth International Conference on Metering and Tariffs for Energy Supply (pp. 6-10). Institution of Engineering and Technology IET. IEE Conference Publication https://doi.org/10.1049/cp:19960467