Abstract

This article describes a method that gives some power quality quantities, like total voltage distortion and voltage unbalance, from relatively sparsely sampled measurements. It is based on an adaptive state observer for the voltage phasors. Requirements for power quality monitoring in power distribution are listed and the results of the laboratory and field tests of new power quality monitoring kWh meters summarised together with field use experience. Finally, the needs and possibilities for future development are discussed.
Original languageEnglish
Pages (from-to)159-163
Number of pages5
JournalPower Engineering Journal
Volume10
Issue number4
DOIs
Publication statusPublished - 1996
MoE publication typeA1 Journal article-refereed

Fingerprint

Smart meters
Power quality
Monitoring
Electric potential

Cite this

Koponen, Pekka ; Seesvuori, R. ; Böstman, R. / Adding power quality monitoring to a smart kWh meter. In: Power Engineering Journal. 1996 ; Vol. 10, No. 4. pp. 159-163.
@article{9e32405da3a846b3820847bf6758e9eb,
title = "Adding power quality monitoring to a smart kWh meter",
abstract = "This article describes a method that gives some power quality quantities, like total voltage distortion and voltage unbalance, from relatively sparsely sampled measurements. It is based on an adaptive state observer for the voltage phasors. Requirements for power quality monitoring in power distribution are listed and the results of the laboratory and field tests of new power quality monitoring kWh meters summarised together with field use experience. Finally, the needs and possibilities for future development are discussed.",
author = "Pekka Koponen and R. Seesvuori and R. B{\"o}stman",
year = "1996",
doi = "10.1049/pe:19960406",
language = "English",
volume = "10",
pages = "159--163",
journal = "Power Engineer",
issn = "1479-8344",
number = "4",

}

Adding power quality monitoring to a smart kWh meter. / Koponen, Pekka; Seesvuori, R.; Böstman, R.

In: Power Engineering Journal, Vol. 10, No. 4, 1996, p. 159-163.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - Adding power quality monitoring to a smart kWh meter

AU - Koponen, Pekka

AU - Seesvuori, R.

AU - Böstman, R.

PY - 1996

Y1 - 1996

N2 - This article describes a method that gives some power quality quantities, like total voltage distortion and voltage unbalance, from relatively sparsely sampled measurements. It is based on an adaptive state observer for the voltage phasors. Requirements for power quality monitoring in power distribution are listed and the results of the laboratory and field tests of new power quality monitoring kWh meters summarised together with field use experience. Finally, the needs and possibilities for future development are discussed.

AB - This article describes a method that gives some power quality quantities, like total voltage distortion and voltage unbalance, from relatively sparsely sampled measurements. It is based on an adaptive state observer for the voltage phasors. Requirements for power quality monitoring in power distribution are listed and the results of the laboratory and field tests of new power quality monitoring kWh meters summarised together with field use experience. Finally, the needs and possibilities for future development are discussed.

U2 - 10.1049/pe:19960406

DO - 10.1049/pe:19960406

M3 - Article

VL - 10

SP - 159

EP - 163

JO - Power Engineer

JF - Power Engineer

SN - 1479-8344

IS - 4

ER -