An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1 Citation (Scopus)

Abstract

In high voltage testing there is a need to measure both the peak value and rms value of power frequency voltage. This paper describes method to calculate accurately both quantities; even when the frequency is not stable. The method can handle waveforms with harmonic content, and an uncertainty of few ppm can be achieved. Method is not sensitive to frequency fluctuation and phase lock loop is not needed.

Original languageEnglish
Title of host publication2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008
PublisherIEEE Institute of Electrical and Electronic Engineers
Pages372-373
Number of pages2
ISBN (Electronic)978-1-4244-2400-9
ISBN (Print)978-1-4244-2399-6
DOIs
Publication statusPublished - 23 Sep 2008
MoE publication typeA4 Article in a conference publication
Event2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008 - Broomfield, CO, United States
Duration: 8 Jun 200813 Jun 2008

Conference

Conference2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008
CountryUnited States
CityBroomfield, CO
Period8/06/0813/06/08

Fingerprint

Electric potential
high voltages
waveforms
Testing
harmonics
electric potential
Uncertainty

Cite this

Suomalainen, E. P., & Hällström, J. (2008). An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data. In 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008 (pp. 372-373). [4574808] IEEE Institute of Electrical and Electronic Engineers . https://doi.org/10.1109/CPEM.2008.4574808
Suomalainen, E. P. ; Hällström, J. / An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data. 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008. IEEE Institute of Electrical and Electronic Engineers , 2008. pp. 372-373
@inproceedings{ca0c7c6816d24e5fafea9d3c8c805e2c,
title = "An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data",
abstract = "In high voltage testing there is a need to measure both the peak value and rms value of power frequency voltage. This paper describes method to calculate accurately both quantities; even when the frequency is not stable. The method can handle waveforms with harmonic content, and an uncertainty of few ppm can be achieved. Method is not sensitive to frequency fluctuation and phase lock loop is not needed.",
author = "Suomalainen, {E. P.} and J. H{\"a}llstr{\"o}m",
year = "2008",
month = "9",
day = "23",
doi = "10.1109/CPEM.2008.4574808",
language = "English",
isbn = "978-1-4244-2399-6",
pages = "372--373",
booktitle = "2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008",
publisher = "IEEE Institute of Electrical and Electronic Engineers",
address = "United States",

}

Suomalainen, EP & Hällström, J 2008, An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data. in 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008., 4574808, IEEE Institute of Electrical and Electronic Engineers , pp. 372-373, 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008, Broomfield, CO, United States, 8/06/08. https://doi.org/10.1109/CPEM.2008.4574808

An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data. / Suomalainen, E. P.; Hällström, J.

2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008. IEEE Institute of Electrical and Electronic Engineers , 2008. p. 372-373 4574808.

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

TY - GEN

T1 - An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data

AU - Suomalainen, E. P.

AU - Hällström, J.

PY - 2008/9/23

Y1 - 2008/9/23

N2 - In high voltage testing there is a need to measure both the peak value and rms value of power frequency voltage. This paper describes method to calculate accurately both quantities; even when the frequency is not stable. The method can handle waveforms with harmonic content, and an uncertainty of few ppm can be achieved. Method is not sensitive to frequency fluctuation and phase lock loop is not needed.

AB - In high voltage testing there is a need to measure both the peak value and rms value of power frequency voltage. This paper describes method to calculate accurately both quantities; even when the frequency is not stable. The method can handle waveforms with harmonic content, and an uncertainty of few ppm can be achieved. Method is not sensitive to frequency fluctuation and phase lock loop is not needed.

UR - http://www.scopus.com/inward/record.url?scp=51949092453&partnerID=8YFLogxK

U2 - 10.1109/CPEM.2008.4574808

DO - 10.1109/CPEM.2008.4574808

M3 - Conference article in proceedings

AN - SCOPUS:51949092453

SN - 978-1-4244-2399-6

SP - 372

EP - 373

BT - 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008

PB - IEEE Institute of Electrical and Electronic Engineers

ER -

Suomalainen EP, Hällström J. An accurate asynchronous calculation method for evaluating peak and RMS values from sampled data. In 2008 Conference on Precision Electromagnetic Measurements Digest, CPEM 2008. IEEE Institute of Electrical and Electronic Engineers . 2008. p. 372-373. 4574808 https://doi.org/10.1109/CPEM.2008.4574808