Analyses of PACTEL passive safety injection experiments GDE-21 through GDE-25

Jari Tuunanen (Corresponding Author), Vesa Riikonen, Jyrki Kouhia, Juhani Vihavainen

Research output: Contribution to journalArticleScientificpeer-review

10 Citations (Scopus)

Abstract

In advanced light water reactors (ALWR), gravity-driven passive safety injection systems (PSIS) replace pump-driven emergency core cooling systems.
PSISs often rely on small density differences and driving forces for natural circulation. In a typical loss-of-coolant accident (LOCA), interactions between different parts of the emergency core cooling system also take place. VTT Energy in Finland, in co-operation with the Lappeenranta University of Technology (LUT), performed five experiments in the PACTEL loop to study PSIS performance during SBLOCAs.
The purpose of the PSIS, a passive core make-up tank (CMT), was to provide high-pressure safety injection water to the primary circuit. The purpose of these experiments was to produce data to validate the current thermal-hydraulic safety codes, and to study the effects of break size on the PSIS behaviour. In all experiments the CMT ran as planned. No problems with rapid condensation in the CMT, as seen in earlier passive safety injection experiments in PACTEL.
The main reason was the new CMT arrangement, with a flow distributor (sparger) installed. The analyses of the test data supported the use of McAdams correlation for calculating the heat transfer from the hot liquid layer to the CMT wall. The use of Nusselt film condensation correlation for condensation at the CMT walls seems correct.
The APROS code simulated successfully the overall primary system behaviour in the GDE-24 experiment, such as timing of the core heat-up at the end of the experiment.
The code had some problems, in the simulation of thermal stratification in the CMT.
Original languageEnglish
Pages (from-to)67-91
JournalNuclear Engineering and Design
Volume180
Issue number1
DOIs
Publication statusPublished - 1998
MoE publication typeA1 Journal article-refereed

Fingerprint

safety
injection
Condensation
experiment
Experiments
condensation
Cooling systems
Codes (standards)
Thermal stratification
cooling systems
emergencies
Loss of coolant accidents
Light water reactors
Water injection
cooling
film condensation
loss of coolant
water injection
light water reactors
Gravitation

Cite this

Tuunanen, Jari ; Riikonen, Vesa ; Kouhia, Jyrki ; Vihavainen, Juhani. / Analyses of PACTEL passive safety injection experiments GDE-21 through GDE-25. In: Nuclear Engineering and Design. 1998 ; Vol. 180, No. 1. pp. 67-91.
@article{e8721b3c58954f28919c2e537d44d24e,
title = "Analyses of PACTEL passive safety injection experiments GDE-21 through GDE-25",
abstract = "In advanced light water reactors (ALWR), gravity-driven passive safety injection systems (PSIS) replace pump-driven emergency core cooling systems. PSISs often rely on small density differences and driving forces for natural circulation. In a typical loss-of-coolant accident (LOCA), interactions between different parts of the emergency core cooling system also take place. VTT Energy in Finland, in co-operation with the Lappeenranta University of Technology (LUT), performed five experiments in the PACTEL loop to study PSIS performance during SBLOCAs. The purpose of the PSIS, a passive core make-up tank (CMT), was to provide high-pressure safety injection water to the primary circuit. The purpose of these experiments was to produce data to validate the current thermal-hydraulic safety codes, and to study the effects of break size on the PSIS behaviour. In all experiments the CMT ran as planned. No problems with rapid condensation in the CMT, as seen in earlier passive safety injection experiments in PACTEL. The main reason was the new CMT arrangement, with a flow distributor (sparger) installed. The analyses of the test data supported the use of McAdams correlation for calculating the heat transfer from the hot liquid layer to the CMT wall. The use of Nusselt film condensation correlation for condensation at the CMT walls seems correct. The APROS code simulated successfully the overall primary system behaviour in the GDE-24 experiment, such as timing of the core heat-up at the end of the experiment. The code had some problems, in the simulation of thermal stratification in the CMT.",
author = "Jari Tuunanen and Vesa Riikonen and Jyrki Kouhia and Juhani Vihavainen",
year = "1998",
doi = "10.1016/S0029-5493(97)00306-3",
language = "English",
volume = "180",
pages = "67--91",
journal = "Nuclear Engineering and Design",
issn = "0029-5493",
publisher = "Elsevier",
number = "1",

}

Analyses of PACTEL passive safety injection experiments GDE-21 through GDE-25. / Tuunanen, Jari (Corresponding Author); Riikonen, Vesa; Kouhia, Jyrki; Vihavainen, Juhani.

In: Nuclear Engineering and Design, Vol. 180, No. 1, 1998, p. 67-91.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - Analyses of PACTEL passive safety injection experiments GDE-21 through GDE-25

AU - Tuunanen, Jari

AU - Riikonen, Vesa

AU - Kouhia, Jyrki

AU - Vihavainen, Juhani

PY - 1998

Y1 - 1998

N2 - In advanced light water reactors (ALWR), gravity-driven passive safety injection systems (PSIS) replace pump-driven emergency core cooling systems. PSISs often rely on small density differences and driving forces for natural circulation. In a typical loss-of-coolant accident (LOCA), interactions between different parts of the emergency core cooling system also take place. VTT Energy in Finland, in co-operation with the Lappeenranta University of Technology (LUT), performed five experiments in the PACTEL loop to study PSIS performance during SBLOCAs. The purpose of the PSIS, a passive core make-up tank (CMT), was to provide high-pressure safety injection water to the primary circuit. The purpose of these experiments was to produce data to validate the current thermal-hydraulic safety codes, and to study the effects of break size on the PSIS behaviour. In all experiments the CMT ran as planned. No problems with rapid condensation in the CMT, as seen in earlier passive safety injection experiments in PACTEL. The main reason was the new CMT arrangement, with a flow distributor (sparger) installed. The analyses of the test data supported the use of McAdams correlation for calculating the heat transfer from the hot liquid layer to the CMT wall. The use of Nusselt film condensation correlation for condensation at the CMT walls seems correct. The APROS code simulated successfully the overall primary system behaviour in the GDE-24 experiment, such as timing of the core heat-up at the end of the experiment. The code had some problems, in the simulation of thermal stratification in the CMT.

AB - In advanced light water reactors (ALWR), gravity-driven passive safety injection systems (PSIS) replace pump-driven emergency core cooling systems. PSISs often rely on small density differences and driving forces for natural circulation. In a typical loss-of-coolant accident (LOCA), interactions between different parts of the emergency core cooling system also take place. VTT Energy in Finland, in co-operation with the Lappeenranta University of Technology (LUT), performed five experiments in the PACTEL loop to study PSIS performance during SBLOCAs. The purpose of the PSIS, a passive core make-up tank (CMT), was to provide high-pressure safety injection water to the primary circuit. The purpose of these experiments was to produce data to validate the current thermal-hydraulic safety codes, and to study the effects of break size on the PSIS behaviour. In all experiments the CMT ran as planned. No problems with rapid condensation in the CMT, as seen in earlier passive safety injection experiments in PACTEL. The main reason was the new CMT arrangement, with a flow distributor (sparger) installed. The analyses of the test data supported the use of McAdams correlation for calculating the heat transfer from the hot liquid layer to the CMT wall. The use of Nusselt film condensation correlation for condensation at the CMT walls seems correct. The APROS code simulated successfully the overall primary system behaviour in the GDE-24 experiment, such as timing of the core heat-up at the end of the experiment. The code had some problems, in the simulation of thermal stratification in the CMT.

U2 - 10.1016/S0029-5493(97)00306-3

DO - 10.1016/S0029-5493(97)00306-3

M3 - Article

VL - 180

SP - 67

EP - 91

JO - Nuclear Engineering and Design

JF - Nuclear Engineering and Design

SN - 0029-5493

IS - 1

ER -