Abstract
Modern partial discharge calibrators often have their lowest range below 1 pC. However, traceable calibration services below 1 pC charges are not widely available, or their uncertainties are relatively high because of low signal levels. Application of charge-sensitive preamplifier for the calibration of partial discharge calibrators provides a promising solution. This new calibration method both improves signal level and integrates the partial discharge pulse. The characteristics of the preamplifier can be corrected using a software, but after that the partial discharge calibrator calibration results have good signal level and repeatability. Estimated uncertainty is below 2 % for 0.1 pC.
Original language | English |
---|---|
Title of host publication | CPEM 2018 - Conference on Precision Electromagnetic Measurements |
Publisher | IEEE Institute of Electrical and Electronic Engineers |
Number of pages | 2 |
ISBN (Electronic) | 978-1-5386-0973-6, 978-1-5386-0974-3 |
DOIs | |
Publication status | Published - 2018 |
MoE publication type | A4 Article in a conference publication |
Event | Conference on Precision Electromagnetic Measurements, CPEM 2018 - Paris, France Duration: 8 Jul 2018 → 13 Jul 2018 |
Conference
Conference | Conference on Precision Electromagnetic Measurements, CPEM 2018 |
---|---|
Abbreviated title | CPEM |
Country/Territory | France |
City | Paris |
Period | 8/07/18 → 13/07/18 |
Keywords
- Calibration
- Measurement
- measurement techniques
- measurement uncertainty
- partial discharges
- measurement