Bilateral three-phase 50 Hz power comparison

    Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

    1 Citation (Scopus)

    Abstract

    This paper describes the results of a bilateral three-phase power comparison between SP, Sweden and MIKES, Finland. A three-phase precision electricity meter was used a transfer reference. Both active and reactive three-phase power measurements were compared.

    Original languageEnglish
    Title of host publication2012 Conference on Precision electromagnetic Measurements
    PublisherIEEE Institute of Electrical and Electronic Engineers
    Pages118-119
    Number of pages2
    ISBN (Electronic)978-1-4673-0442-9
    ISBN (Print)978-1-4673-0439-9
    DOIs
    Publication statusPublished - 3 Oct 2012
    MoE publication typeA4 Article in a conference publication
    Event2012 Conference on Precision Electromagnetic Measurements, CPEM 2012 - Washington, DC, United States
    Duration: 1 Jul 20126 Jul 2012

    Conference

    Conference2012 Conference on Precision Electromagnetic Measurements, CPEM 2012
    Abbreviated titleCPEM
    Country/TerritoryUnited States
    CityWashington, DC
    Period1/07/126/07/12

    Keywords

    • measurement standards
    • reactive power
    • three-phase electric power
    • uncertainty

    Fingerprint

    Dive into the research topics of 'Bilateral three-phase 50 Hz power comparison'. Together they form a unique fingerprint.

    Cite this