Abstract
Design and construction of a calibrator for lightning and switching impulse voltage measuring instruments is presented. The operating voltage range is from 50 mV to 300 V. The estimated uncertainty for the peak value is 0,03% and for front time and time to half value less than 1%.
Original language | English |
---|---|
Pages (from-to) | 286-287 |
Number of pages | 2 |
Journal | CPEM Digest (Conference on Precision Electromagnetic Measurements) |
Publication status | Published - 1 Jan 2002 |
MoE publication type | A4 Article in a conference publication |