Characteristics of a double-orifice nebulizer

Wlodzimierz Pilacinski, Krzysztof Szewczyk, Matti Lehtimäki, Klaus Willeke (Corresponding Author)

Research output: Contribution to journalArticleScientificpeer-review

4 Citations (Scopus)

Abstract

Aerosol generation in a pneumatic nebulizer with a double-orifice nozzle was studied in the particle size range of 0.8–10 μm. It was found that the aerosol generation rate can be changed without significant changes in the aerosol size distribution by changing the distance between the orifices. The aerosol size distribution was modified by changing the input air pressure. A Wright type nebulizer was modified to produce a wider spectrum of particles.
Original languageEnglish
Pages (from-to)977-982
JournalJournal of Aerosol Science
Volume21
Issue number7
DOIs
Publication statusPublished - 1990
MoE publication typeA1 Journal article-refereed

Fingerprint

Orifices
Aerosols
particle size
aerosol
atmospheric pressure
Pneumatics
Nozzles
Particle size
Air

Cite this

Pilacinski, W., Szewczyk, K., Lehtimäki, M., & Willeke, K. (1990). Characteristics of a double-orifice nebulizer. Journal of Aerosol Science, 21(7), 977-982. https://doi.org/10.1016/0021-8502(90)90167-V
Pilacinski, Wlodzimierz ; Szewczyk, Krzysztof ; Lehtimäki, Matti ; Willeke, Klaus. / Characteristics of a double-orifice nebulizer. In: Journal of Aerosol Science. 1990 ; Vol. 21, No. 7. pp. 977-982.
@article{e336cd470ae64bc392e786eb88ddca1f,
title = "Characteristics of a double-orifice nebulizer",
abstract = "Aerosol generation in a pneumatic nebulizer with a double-orifice nozzle was studied in the particle size range of 0.8–10 μm. It was found that the aerosol generation rate can be changed without significant changes in the aerosol size distribution by changing the distance between the orifices. The aerosol size distribution was modified by changing the input air pressure. A Wright type nebulizer was modified to produce a wider spectrum of particles.",
author = "Wlodzimierz Pilacinski and Krzysztof Szewczyk and Matti Lehtim{\"a}ki and Klaus Willeke",
year = "1990",
doi = "10.1016/0021-8502(90)90167-V",
language = "English",
volume = "21",
pages = "977--982",
journal = "Journal of Aerosol Science",
issn = "0021-8502",
publisher = "Elsevier",
number = "7",

}

Pilacinski, W, Szewczyk, K, Lehtimäki, M & Willeke, K 1990, 'Characteristics of a double-orifice nebulizer', Journal of Aerosol Science, vol. 21, no. 7, pp. 977-982. https://doi.org/10.1016/0021-8502(90)90167-V

Characteristics of a double-orifice nebulizer. / Pilacinski, Wlodzimierz; Szewczyk, Krzysztof; Lehtimäki, Matti; Willeke, Klaus (Corresponding Author).

In: Journal of Aerosol Science, Vol. 21, No. 7, 1990, p. 977-982.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - Characteristics of a double-orifice nebulizer

AU - Pilacinski, Wlodzimierz

AU - Szewczyk, Krzysztof

AU - Lehtimäki, Matti

AU - Willeke, Klaus

PY - 1990

Y1 - 1990

N2 - Aerosol generation in a pneumatic nebulizer with a double-orifice nozzle was studied in the particle size range of 0.8–10 μm. It was found that the aerosol generation rate can be changed without significant changes in the aerosol size distribution by changing the distance between the orifices. The aerosol size distribution was modified by changing the input air pressure. A Wright type nebulizer was modified to produce a wider spectrum of particles.

AB - Aerosol generation in a pneumatic nebulizer with a double-orifice nozzle was studied in the particle size range of 0.8–10 μm. It was found that the aerosol generation rate can be changed without significant changes in the aerosol size distribution by changing the distance between the orifices. The aerosol size distribution was modified by changing the input air pressure. A Wright type nebulizer was modified to produce a wider spectrum of particles.

U2 - 10.1016/0021-8502(90)90167-V

DO - 10.1016/0021-8502(90)90167-V

M3 - Article

VL - 21

SP - 977

EP - 982

JO - Journal of Aerosol Science

JF - Journal of Aerosol Science

SN - 0021-8502

IS - 7

ER -