Abstract
A regional key comparison of dc voltage ratio has been carried out in Europe. The method to evaluate the comparison reference value, the resulting degrees of equivalence for the voltage ratios 1000 V/10 V and 100 V/10 V and the link to the corresponding worldwide key comparison CCEM-K8 are reported.
Original language | English |
---|---|
Pages (from-to) | 576-579 |
Number of pages | 4 |
Journal | IEEE Transactions on Instrumentation and Measurement |
Volume | 54 |
Issue number | 2 |
DOIs | |
Publication status | Published - 1 Apr 2005 |
MoE publication type | Not Eligible |
Keywords
- Key comparisons
- Voltage dividers
- Voltage ratio measurements