Comparison of length standards between the CMA and the VNIIM

L. Abramova, V. Baratov, V. Fedorin, L. Khavinson, E. Latigneva, K. Riski, E. Ikonen, A. Lassila

Research output: Contribution to journalReview ArticleScientificpeer-review

1 Citation (Scopus)

Abstract

Results are presented from a comparison of a 1 m gauge block and line scale. The largest difference between the average results was 100 nm for the 200 mm line of the scale.

Original languageEnglish
Pages (from-to)29-33
Number of pages5
JournalMetrologia
Volume33
Issue number1
DOIs
Publication statusPublished - 1 Dec 1996
MoE publication typeNot Eligible

Fingerprint

Gage blocks

Cite this

Abramova, L., Baratov, V., Fedorin, V., Khavinson, L., Latigneva, E., Riski, K., ... Lassila, A. (1996). Comparison of length standards between the CMA and the VNIIM. Metrologia, 33(1), 29-33. https://doi.org/10.1088/0026-1394/33/1/4
Abramova, L. ; Baratov, V. ; Fedorin, V. ; Khavinson, L. ; Latigneva, E. ; Riski, K. ; Ikonen, E. ; Lassila, A. / Comparison of length standards between the CMA and the VNIIM. In: Metrologia. 1996 ; Vol. 33, No. 1. pp. 29-33.
@article{19422f01f3c14758aa03cce2a2d292be,
title = "Comparison of length standards between the CMA and the VNIIM",
abstract = "Results are presented from a comparison of a 1 m gauge block and line scale. The largest difference between the average results was 100 nm for the 200 mm line of the scale.",
author = "L. Abramova and V. Baratov and V. Fedorin and L. Khavinson and E. Latigneva and K. Riski and E. Ikonen and A. Lassila",
year = "1996",
month = "12",
day = "1",
doi = "10.1088/0026-1394/33/1/4",
language = "English",
volume = "33",
pages = "29--33",
journal = "Metrologia",
issn = "0026-1394",
publisher = "Institute of Physics IOP",
number = "1",

}

Abramova, L, Baratov, V, Fedorin, V, Khavinson, L, Latigneva, E, Riski, K, Ikonen, E & Lassila, A 1996, 'Comparison of length standards between the CMA and the VNIIM', Metrologia, vol. 33, no. 1, pp. 29-33. https://doi.org/10.1088/0026-1394/33/1/4

Comparison of length standards between the CMA and the VNIIM. / Abramova, L.; Baratov, V.; Fedorin, V.; Khavinson, L.; Latigneva, E.; Riski, K.; Ikonen, E.; Lassila, A.

In: Metrologia, Vol. 33, No. 1, 01.12.1996, p. 29-33.

Research output: Contribution to journalReview ArticleScientificpeer-review

TY - JOUR

T1 - Comparison of length standards between the CMA and the VNIIM

AU - Abramova, L.

AU - Baratov, V.

AU - Fedorin, V.

AU - Khavinson, L.

AU - Latigneva, E.

AU - Riski, K.

AU - Ikonen, E.

AU - Lassila, A.

PY - 1996/12/1

Y1 - 1996/12/1

N2 - Results are presented from a comparison of a 1 m gauge block and line scale. The largest difference between the average results was 100 nm for the 200 mm line of the scale.

AB - Results are presented from a comparison of a 1 m gauge block and line scale. The largest difference between the average results was 100 nm for the 200 mm line of the scale.

UR - http://www.scopus.com/inward/record.url?scp=0029715774&partnerID=8YFLogxK

U2 - 10.1088/0026-1394/33/1/4

DO - 10.1088/0026-1394/33/1/4

M3 - Review Article

VL - 33

SP - 29

EP - 33

JO - Metrologia

JF - Metrologia

SN - 0026-1394

IS - 1

ER -

Abramova L, Baratov V, Fedorin V, Khavinson L, Latigneva E, Riski K et al. Comparison of length standards between the CMA and the VNIIM. Metrologia. 1996 Dec 1;33(1):29-33. https://doi.org/10.1088/0026-1394/33/1/4