Abstract
A method for pulverized coal combustion aerosol mass concentration measurements with a dilution system and tapered element oscillating microbalance (TEOM) is introduced. The TEOM microbalance method gives continuous information about mass concentration variations in a minute scale time resolution. Particle upper size limit is chosen with a cyclone.
Original language | English |
---|---|
Pages (from-to) | 639-642 |
Journal | Journal of Aerosol Science |
Volume | 23 |
Issue number | Suppl. 1 |
DOIs | |
Publication status | Published - 1992 |
MoE publication type | A1 Journal article-refereed |
Event | 1992 European Aerosol Conference Proceedings - Oxford, United Kingdom Duration: 7 Sept 1992 → 11 Sept 1992 |