Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain

Tiina Seppälä, Iiro Auterinen, Carita Aschan, Tom Serén, Judit Benczik, Marjatta Snellman, René Huiskamp, Usama Abo Ramadan, Leena Kankaanranta, Heikki Joensuu, Sauli Savolainen*

*Corresponding author for this work

    Research output: Contribution to journalArticleScientificpeer-review

    6 Citations (Scopus)

    Abstract

    Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the brain of dogs before starting the clinical trials. A dose planning procedure was developed and uncertainties of the epithermal neutron-induced doses were estimated. The accuracy of the method of computing physical doses was assessed by comparing with in vivo dosimetry. Individual radiation dose plans were computed using magnetic resonance images of the heads of 15 Beagle dogs and the computational model of the FiR 1 epithermal neutron beam. For in vivo dosimetry, the thermal neutron fluences were measured using Mn activation foils and the gamma-ray doses with MCP-7s type thermoluminescent detectors placed both on the skin surface of the head and in the oral cavity. The degree of uncertainty of the reference doses at the thermal neutron maximum was estimated using a dose-planning program. The estimated uncertainty (±1 standard deviation) in the total physical reference dose was ±8.9%. The calculated and the measured dose values agreed within the uncertainties at the point of beam entry. The conclusion is that the dose delivery to the tissue can be verified in a practical and reliable fashion by placing an activation dosimeter and a TL detector at the beam entry point on the skin surface with homogeneous tissues below. However, the point doses cannot be calculated correctly in the inhomogeneous area near air cavities of the head model with this type of dose-planning program. This calls for attention in dose planning in human clinical trials in the corresponding areas.

    Original languageEnglish
    Pages (from-to)2629-2640
    Number of pages12
    JournalMedical Physics
    Volume29
    Issue number11
    DOIs
    Publication statusPublished - 1 Nov 2002
    MoE publication typeA1 Journal article-refereed

    Keywords

    • Boron neutron capture therapy
    • Dose planning
    • Dose verification
    • Dosimetry
    • Epithermal neutrons

    Fingerprint

    Dive into the research topics of 'Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain'. Together they form a unique fingerprint.

    Cite this