    Electric bus charger in the prototype electric bus "Muuli", the Mule was measured for power quality and simulation model was constructed with the help of these measurements. The Charger had quite high harmonics in the current. Simulation model had also low value inductor filter to emulate current waveform shape from the measurements. The model was tuned to be accurate at about 20kW power output. High THD value of the charger, about 32% is by no means ok and could cause power quality problems. Future work with the model will focus on finding candidates for filtering the harmonics to more acceptable level.
    Original languageEnglish
    PublisherVTT Technical Research Centre of Finland
    Number of pages17
    Publication statusPublished - 2015
    MoE publication typeD4 Published development or research report or study

    Publication series

    SeriesHelsinki University of Technology: Systems Analysis Laboratory. A: Research Reports
    VolumeVTT-R-03822-15

      Fingerprint

    Keywords

    • power quality
    • current harmonics
    • simulation

    Cite this