Abstract
We studied effects of interturn spacing on AC losses and DC critical currents of single layer R&W coils wound from multifilamentary, untwisted Bi-2223/Ag tape. The losses at currents below the critical current increased proportional to i = (I0/Ic)n, where n values were 3.6, 3.3, and 3 for coils with interturn gap 4 mm, 1 mm and 0.1 mm, respectively. At currents below Ic AC losses increased with decreasing interturn gap. We suppose that the observed loss increase is caused by the increase of magnetization losses, while self-field losses remain practically unchanged.
| Original language | English |
|---|---|
| Pages (from-to) | 673-676 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Applied Superconductivity |
| Volume | 10 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 1 Jan 2000 |
| MoE publication type | A4 Article in a conference publication |
| Event | The 16th International Conference on Magnet Tehnolopgy - Tallahassee, FL, USA Duration: 26 Sept 1999 → 2 Oct 1999 |
Fingerprint
Dive into the research topics of 'Effect of interturn spacing on AC loss of single layer Bi-2223/Ag coils'. Together they form a unique fingerprint.Cite this