Abstract
The interaction of copper with sulfide-containing simulated saline groundwater is studied by electrochemical techniques (voltammetry, current-time transients, and electrochemical impedance spectroscopy, EIS) complemented with surface and cross-sectional microscopic observations and energy dispersive spectroscopic analyses. Both experimental findings and quantitative interpretation of EIS data using previously published kinetic models indicate that no continuous adherent barrier-type layer is formed on Cu in sulfide-containing groundwater, thus precluding the possibility of the development of localized corrosion modes.
Original language | English |
---|---|
Article number | 041505 |
Number of pages | 12 |
Journal | Journal of the Electrochemical Society |
Volume | 171 |
Issue number | 4 |
DOIs | |
Publication status | Published - 29 Apr 2024 |
MoE publication type | A1 Journal article-refereed |
Keywords
- copper
- corrosion modeling
- localized corrosion
- passivity