European SMR station blackout thermal–hydraulic analysis with the Apros system code

Marton Szogradi*, Fares Alblouwy

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

16 Downloads (Pure)

Abstract

Recent years have seen the global development of small modular reactors (SMRs), introducing many innovative design concepts, particularly in safety systems focusing at the optimization of economic feasibility and passive reliability. Vendors, regulatory bodies and technical support organizations have been preparing for the deployment of various first-of-a-kind projects, along with international organizations who aim to streamline such efforts. The Euratom-funded ELSMOR project contributed to this work by developing the European SMR (E-SMR) dataset, which integrates publicly available information from different SMR designs. This dataset has been used to simulate various station blackout (SBO) and loss-of-coolant accident (LOCA) transients to better understand the safety aspects of design basis accidents in light-water SMRs, with a highlight on the performance of passive safety systems. This paper presents the analysis of an SBO scenario using the Apros code, showcasing the operation of a passive heat removal system, supported by the water wall and hydroaccumulators. The study also examines the interactions of these safety systems. Additionally, the paper discusses stratification processes in the water wall and other factors related to sensitivity analysis and performance optimization.
Original languageEnglish
Article number113888
JournalNuclear Engineering and Design
Volume435
DOIs
Publication statusPublished - 15 Apr 2025
MoE publication typeA1 Journal article-refereed

Funding

This project has received funding from the Euratom research and training programme 2014-2018 under Grant Agreement No. 847553.

Keywords

  • E-SMR
  • SBO
  • SMR
  • Apros

Fingerprint

Dive into the research topics of 'European SMR station blackout thermal–hydraulic analysis with the Apros system code'. Together they form a unique fingerprint.

Cite this