Abstract
The high-voltage DC measuring system based on bandgap voltage references has been used for high accuracy with low dynamic resistance up to 20 kV. The measuring system is stable output over a wide range of operating current and ambient temperature, and it is insensitive to effects due to leakage currents. One of the most important parameters of a reference system is its long-term stability. This paper describes the long-term performance of a high-voltage DC reference measuring system based on bandgap voltage references.
| Original language | English |
|---|---|
| Title of host publication | 29th Conference on Precision Electromagnetic Measurements (CPEM 2014) |
| Publisher | IEEE Institute of Electrical and Electronic Engineers |
| Pages | 376-377 |
| ISBN (Electronic) | 978-1-4799-2479-0 |
| ISBN (Print) | 978-1-4799-5205-2 |
| DOIs | |
| Publication status | Published - 12 Sept 2014 |
| MoE publication type | A4 Article in a conference publication |
| Event | 29th Conference on Precision Electromagnetic Measurements, CPEM 2014 - Rio de Janeiro, Brazil Duration: 24 Aug 2014 → 29 Aug 2014 |
Publication series
| Series | CPEM Digest (Conference on Precision Electromagnetic Measurements) |
|---|---|
| Volume | 29 |
| ISSN | 0589-1485 |
Conference
| Conference | 29th Conference on Precision Electromagnetic Measurements, CPEM 2014 |
|---|---|
| Abbreviated title | CPEM 2014 |
| Country/Territory | Brazil |
| City | Rio de Janeiro |
| Period | 24/08/14 → 29/08/14 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- High-voltage techniques
- measurement standards
- measurement techniques
- measurement uncertainty
- precision measurements
Fingerprint
Dive into the research topics of 'Evaluation of long-term stability of HVDC measuring system based on bandgap references'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver