Experimental investigation of air flows through large openings in a horozontal partition

Krzysztof Klobut, Kai Siren

Research output: Book/ReportReportProfessional

Original languageEnglish
Place of PublicationEspoo
PublisherHelsinki University of Technology
Number of pages75
ISBN (Print)951-22-2023-7
Publication statusPublished - 1994
MoE publication typeD4 Published development or research report or study

Publication series

NameHelsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report
No.B35

Cite this

Klobut, K., & Siren, K. (1994). Experimental investigation of air flows through large openings in a horozontal partition. Espoo: Helsinki University of Technology. Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report, No. B35
Klobut, Krzysztof ; Siren, Kai. / Experimental investigation of air flows through large openings in a horozontal partition. Espoo : Helsinki University of Technology, 1994. 75 p. (Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report; No. B35).
@book{fb224cb95c26487fac137d504c6b7bcf,
title = "Experimental investigation of air flows through large openings in a horozontal partition",
author = "Krzysztof Klobut and Kai Siren",
year = "1994",
language = "English",
isbn = "951-22-2023-7",
series = "Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report",
publisher = "Helsinki University of Technology",
number = "B35",
address = "Finland",

}

Klobut, K & Siren, K 1994, Experimental investigation of air flows through large openings in a horozontal partition. Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report, no. B35, Helsinki University of Technology, Espoo.

Experimental investigation of air flows through large openings in a horozontal partition. / Klobut, Krzysztof; Siren, Kai.

Espoo : Helsinki University of Technology, 1994. 75 p. (Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report; No. B35).

Research output: Book/ReportReportProfessional

TY - BOOK

T1 - Experimental investigation of air flows through large openings in a horozontal partition

AU - Klobut, Krzysztof

AU - Siren, Kai

PY - 1994

Y1 - 1994

M3 - Report

SN - 951-22-2023-7

T3 - Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report

BT - Experimental investigation of air flows through large openings in a horozontal partition

PB - Helsinki University of Technology

CY - Espoo

ER -

Klobut K, Siren K. Experimental investigation of air flows through large openings in a horozontal partition. Espoo: Helsinki University of Technology, 1994. 75 p. (Helsinki University of Technology, Laboratory of Heating, Ventilating and Air-Conditioning, Report; No. B35).