Fast resistive attenuators for high accuracy measurements of LI voltages

Yuri Y. Chekurov, Jari K. Hällström

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

3 Citations (Scopus)

Abstract

Design, construction and calibration of compact, inexpensive and fast resistive attenuators for lightning impulse or surge voltage measurements up to 1.5 kV is presented. Estimated uncertainty of attenuator ratio is less than 100 ppm (k=2). The input resistance of attenuators is 50 Ω ±1 % and the rise-time is less than 1 ns. The calibration procedure of the attenuators is described.

Original languageEnglish
Title of host publication2004 Conference on Precision Electromagnetic Measurements Digest, CPEM 2004
PublisherIEEE Institute of Electrical and Electronic Engineers
Pages328-329
Number of pages2
ISBN (Electronic)0-7803-8494-6
ISBN (Print)0-7803-8493-8
DOIs
Publication statusPublished - 1 Dec 2004
MoE publication typeA4 Article in a conference publication
Event2004 Conference on Precision Electromagnetic Measurements, CPEM 2004 - London, United Kingdom