Abstract
Two anemometers, Rosemount Solid State and Hydro-Tech
WS-3, designed for wind measurements in icing conditions
were calibrated in a wind tunnel and compared in field
tests. A significant difference between the velocity
output was observed in the comparison.
Original language | English |
---|---|
Title of host publication | 7th International Workshop on Atmospheric Icing of Structures IWAIS '96 |
Editors | J. Laflamme, M. Farzaneh |
Place of Publication | Chicoutimi |
Pages | 107-110 |
Publication status | Published - 1996 |
MoE publication type | A4 Article in a conference publication |
Event | 7th International Workshop on Atmospheric Icing of Structures IWAIS'96 - Chicoutimi, Canada Duration: 3 Jun 1996 → 6 Jun 1996 |
Workshop
Workshop | 7th International Workshop on Atmospheric Icing of Structures IWAIS'96 |
---|---|
Country/Territory | Canada |
City | Chicoutimi |
Period | 3/06/96 → 6/06/96 |
Keywords
- anemometers
- wind measurements
- icing environments