TY - JOUR
T1 - Final report on EURAMET.T-K6.1
T2 - Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70°C to +20°C
AU - Heinonen, Martti
AU - Zvizdic, Davor
AU - Sestan, Danijel
PY - 2013
Y1 - 2013
N2 - As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point −70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties.
AB - As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point −70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties.
KW - measurement
KW - temperatures
UR - https://www.bipm.org/utils/common/pdf/final_reports/T/K6/EURAMET.T-K6.1.pdf
U2 - 10.1088/0026-1394/50/1A/03009
DO - 10.1088/0026-1394/50/1A/03009
M3 - Article
SN - 0026-1394
VL - 50
JO - Metrologia
JF - Metrologia
IS - 1A
ER -