Harmonic Power Standard of VTT MIKES

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1 Citation (Scopus)

Abstract

This paper describes the new single-phase harmonic power standard of VTT MIKES. The standard is based on a custom digitizer, which is developed for AC metrology in the laboratory, and for field measurement campaigns. Test signal generation uses a dual channel arbitrary function generator, a voltage amplifier, and a transconductance amplifier. Reference voltage and current measurements are respectively based on a capacitive-resistive voltage divider and two different types of resistive shunt designs.
Original languageEnglish
Title of host publicationCPEM 2018 - Conference on Precision Electromagnetic Measurements
PublisherInstitute of Electrical and Electronic Engineers IEEE
Number of pages2
ISBN (Electronic)978-1-5386-0974-3 , 978-1-5386-0973-6
DOIs
Publication statusPublished - 2018
MoE publication typeNot Eligible
EventConference on Precision Electromagnetic Measurements, CPEM 2018 - Paris, France
Duration: 8 Jul 201813 Jul 2018

Conference

ConferenceConference on Precision Electromagnetic Measurements, CPEM 2018
Abbreviated titleCPEM
CountryFrance
CityParis
Period8/07/1813/07/18

Fingerprint

Voltage dividers
Function generators
Voltage measurement
Transconductance
Electric current measurement
Electric potential

Keywords

  • Measurement
  • measurement standards
  • measurement uncertainty
  • power measurement

Cite this

Lehtonen, T. (2018). Harmonic Power Standard of VTT MIKES. In CPEM 2018 - Conference on Precision Electromagnetic Measurements Institute of Electrical and Electronic Engineers IEEE. https://doi.org/10.1109/CPEM.2018.8501017
Lehtonen, Tapio. / Harmonic Power Standard of VTT MIKES. CPEM 2018 - Conference on Precision Electromagnetic Measurements. Institute of Electrical and Electronic Engineers IEEE, 2018.
@inproceedings{c3b00075432c4b419b676732033b2d0b,
title = "Harmonic Power Standard of VTT MIKES",
abstract = "This paper describes the new single-phase harmonic power standard of VTT MIKES. The standard is based on a custom digitizer, which is developed for AC metrology in the laboratory, and for field measurement campaigns. Test signal generation uses a dual channel arbitrary function generator, a voltage amplifier, and a transconductance amplifier. Reference voltage and current measurements are respectively based on a capacitive-resistive voltage divider and two different types of resistive shunt designs.",
keywords = "Measurement, measurement standards, measurement uncertainty, power measurement",
author = "Tapio Lehtonen",
note = "Extended abstract",
year = "2018",
doi = "10.1109/CPEM.2018.8501017",
language = "English",
booktitle = "CPEM 2018 - Conference on Precision Electromagnetic Measurements",
publisher = "Institute of Electrical and Electronic Engineers IEEE",
address = "United States",

}

Lehtonen, T 2018, Harmonic Power Standard of VTT MIKES. in CPEM 2018 - Conference on Precision Electromagnetic Measurements. Institute of Electrical and Electronic Engineers IEEE, Conference on Precision Electromagnetic Measurements, CPEM 2018, Paris, France, 8/07/18. https://doi.org/10.1109/CPEM.2018.8501017

Harmonic Power Standard of VTT MIKES. / Lehtonen, Tapio.

CPEM 2018 - Conference on Precision Electromagnetic Measurements. Institute of Electrical and Electronic Engineers IEEE, 2018.

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

TY - GEN

T1 - Harmonic Power Standard of VTT MIKES

AU - Lehtonen, Tapio

N1 - Extended abstract

PY - 2018

Y1 - 2018

N2 - This paper describes the new single-phase harmonic power standard of VTT MIKES. The standard is based on a custom digitizer, which is developed for AC metrology in the laboratory, and for field measurement campaigns. Test signal generation uses a dual channel arbitrary function generator, a voltage amplifier, and a transconductance amplifier. Reference voltage and current measurements are respectively based on a capacitive-resistive voltage divider and two different types of resistive shunt designs.

AB - This paper describes the new single-phase harmonic power standard of VTT MIKES. The standard is based on a custom digitizer, which is developed for AC metrology in the laboratory, and for field measurement campaigns. Test signal generation uses a dual channel arbitrary function generator, a voltage amplifier, and a transconductance amplifier. Reference voltage and current measurements are respectively based on a capacitive-resistive voltage divider and two different types of resistive shunt designs.

KW - Measurement

KW - measurement standards

KW - measurement uncertainty

KW - power measurement

UR - http://www.scopus.com/inward/record.url?scp=85057005561&partnerID=8YFLogxK

U2 - 10.1109/CPEM.2018.8501017

DO - 10.1109/CPEM.2018.8501017

M3 - Conference article in proceedings

BT - CPEM 2018 - Conference on Precision Electromagnetic Measurements

PB - Institute of Electrical and Electronic Engineers IEEE

ER -

Lehtonen T. Harmonic Power Standard of VTT MIKES. In CPEM 2018 - Conference on Precision Electromagnetic Measurements. Institute of Electrical and Electronic Engineers IEEE. 2018 https://doi.org/10.1109/CPEM.2018.8501017