Abstract
In this work we have reviewed three traditional hazard analysis methods, FTA, FMEA
and HAZOP, as well as a recently developed STPA method that is based on the
STAMP model. After giving an overview and case examples of the different methods,
the methods are compared with each other, and their use in the context of nuclear
domain I&C systems is discussed.
and HAZOP, as well as a recently developed STPA method that is based on the
STAMP model. After giving an overview and case examples of the different methods,
the methods are compared with each other, and their use in the context of nuclear
domain I&C systems is discussed.
Original language | English |
---|---|
Place of Publication | Espoo |
Publisher | VTT Technical Research Centre of Finland |
Number of pages | 64 |
Publication status | Published - 2014 |
MoE publication type | D4 Published development or research report or study |
Publication series
Series | VTT Research Report |
---|---|
Volume | VTT-R-03821-14 |
Keywords
- hazard analysis
- FTA
- FMEA
- HAZOP
- STAMP
- STPA