Human exposure to pulsed fields in the frequency range from 6 to 100 GHz

  • Aalto University
  • Nagoya Institute of Technology
  • nLIGHT Finland

Research output: Contribution to journal › Article › Scientific › peer-review

Abstract

Restrictions on human exposure to electromagnetic waves at frequencies higher than 3-10 GHz are defined in terms of the incident power density to prevent excessive temperature rise in superficial tissue. However, international standards and guidelines differ in their definitions of how the power density is interpreted for brief exposures. This study investigated how the temperature rise was affected by exposure duration at frequencies higher than 6 GHz. Far-field exposure of the human face to pulses shorter than 10 s at frequencies from 6 to 100 GHz was modelled using the finite-difference time-domain method. The bioheat transfer equation was used for thermal modelling. We investigated the effects of frequency, polarization, exposure duration, and depth below the skin surface on the temperature rise. The results indicated limitations in the current human exposure guidelines and showed that radiant exposure, i.e. energy absorption per unit area, can be used to limit temperature rise for pulsed exposure. The data are useful for the development of human exposure guidelines at frequencies higher than 6 GHz.
Original languageEnglish
Pages (from-to)6980-6992
Number of pages13
JournalPhysics in Medicine and Biology
Volume62
Issue number17
DOIs
Publication statusPublished - 9 Aug 2017
MoE publication typeA1 Journal article-refereed

Keywords

  • bioheat transfer
  • dosimetry
  • human exposure
  • microwave fields effects
  • millimetre waves
  • pulsed fields