Implementation and characterization of reference measuring system for the calibration of high voltage source at very low frequency (VLF)

Ahmet Merev*, Sami Özer, Serkan Dedeoglu

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

2 Citations (Scopus)

Abstract

Very Low Frequency (VLF) high voltage measuring system including the resistive high-voltage divider has been designed, developed and implemented from DC to 1 Hz up to 120 kV. The divider consists of three modules stacked on top of each other. The characterization of VLF high voltage measuring system has been performed by the calibration of the scale factor with the precision HVDC measuring system directly to determine the performance of it. The expanded uncertainty value of VLF high voltage measuring system was determined as 0.05% which meets the requirement of IEC 60060-2: 2010. This measuring system has been currently used in TUBİTAK UME (National Metrology Institute of Turkey) as a reference measuring system for the calibration of VLF high voltage test devices in-house and on-site.
Original languageEnglish
Pages (from-to)3769-3777
Number of pages9
JournalElectrical Engineering
Volume104
Issue number6
DOIs
Publication statusPublished - Dec 2022
MoE publication typeA1 Journal article-refereed

Keywords

  • High-voltage dividers
  • High-voltage techniques
  • Measurement
  • Measurement standards
  • Metrology
  • Uncertainty
  • VLF

Fingerprint

Dive into the research topics of 'Implementation and characterization of reference measuring system for the calibration of high voltage source at very low frequency (VLF)'. Together they form a unique fingerprint.

Cite this