Skip to main navigation Skip to search Skip to main content

Improved corrosion performance of biodegradable magnesium in simulated inflammatory condition via drug-loaded plasma electrolytic oxidation coatings

  • Aidin Bordbar-Khiabani
  • , Benyamin Yarmand
  • , Samin Sharifi-Asl
  • , Masoud Mozafari*
  • *Corresponding author for this work
  • Materials and Energy Research Center (MERC)
  • Iran University of Medical Sciences
  • University of California, Berkeley

Research output: Contribution to journalArticleScientificpeer-review

Abstract

Magnesium and its alloys are nowadays one of the most common biodegradable materials for orthopedic applications. Following the implantation of an orthopedic device, near the implant hydrogen peroxide and acidic environment are generated by an inflammatory reaction. In this study, a betamethasone sodium phosphate (BSP) layer as an anti-inflammatory drug was prepared on plasma electrolytic oxidation (PEO) coatings by a dip-coating process on magnesium alloys. X-ray diffraction (XRD), Fourier transformation infrared spectroscopy (FTIR), field emission scanning electron microscopy equipped with energy-dispersive X-ray spectroscopy (FESEM-EDX) and atomic force microscopy (AFM) were utilized for characterization studies. The results showed that the BSP layer successfully sealed the PEO coating. The corrosion resistance of the uncoated and coated samples was evaluated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization tests in normal and simulated inflammatory conditions. During the simulated inflammation, the samples indicated an enhanced corrosion rate compared to that of normal condition. The results in the inflammatory environment showed that the corrosion resistance of the PEO/BSP coating was remarkably improved by two or three orders of magnitude, compared with uncoated Mg alloy and the PEO coating. Immersion tests show that the BSP layer significantly improves the bioactivity of PEO-coated Mg alloy in simulated body fluid (SBF). Moreover, the in vitro release behavior of drug loaded PEO coating was evaluated.

Original languageEnglish
Article number122003
JournalMaterials Chemistry and Physics
Volume239
DOIs
Publication statusPublished - 1 Jan 2020
MoE publication typeA1 Journal article-refereed

Funding

This research work has been supported with research grant (NO. 247383 ) by Materials and Energy Research Center (MERC), Tehran, Iran.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure

Keywords

  • Biodegradable implants
  • Corrosion resistance
  • Drug-coated implants
  • Magnesium
  • Plasma electrolytic oxidation

Fingerprint

Dive into the research topics of 'Improved corrosion performance of biodegradable magnesium in simulated inflammatory condition via drug-loaded plasma electrolytic oxidation coatings'. Together they form a unique fingerprint.

Cite this