In-service inspection of steam generators at Loviisa

Leo Poikonen, Kari Lahdenperä

    Research output: Contribution to journalArticleScientificpeer-review

    Abstract

    In-service inspection of the steam generators at the Loviisa nuclear power plant is being performed by means of an inspection manipulator which can be equipped with both ultrasonic and eddy current measuring devices.
    Original languageEnglish
    Pages (from-to)17 - 18
    Number of pages2
    JournalNuclear Europe
    Issue number6
    Publication statusPublished - 1986
    MoE publication typeNot Eligible

    Fingerprint Dive into the research topics of 'In-service inspection of steam generators at Loviisa'. Together they form a unique fingerprint.