Skip to main navigation Skip to search Skip to main content

Integrating residential heating and cooling flexibility into operational energy system optimization

Research output: Thesis › Dissertation › Collection of Articles

Abstract

Electrification of historically fossil-fuelled sectors is seen as one of the most feasible decarbonization pathways. However, it requires significant expansion of variable renewable energy (VRE) production, increasing the need for flexible demand. Buildings could supply such flexibility by harnessing the inherent thermal inertia in their heating, cooling, ventilation, and domestic hot water systems.

This thesis investigated integrating simplified lumped-capacitance building thermal models into energy-market-scale modelling to capture the benefits of widespread building energy flexibility (BEF). A synthetic average archetype building modelling approach was developed to depict the thermal dynamics of building stocks compatible with mixed-integer-linear-programming-based energy system optimization frameworks. This approach was compared against dedicated building simulation software, as well as demonstrated for building and district-level optimal energy management. Lastly, the impacts of Finnish electric heating and cooling flexibility in the North European energy system were analysed.

The observed annual heating cost savings between 3–20% of the building and district-scale optimal energy management align with existing literature, with similar savings around 2–21% found in the energy-market-scale simulations. Ultimately, these correspond to 0.16–0.87 €/m2 of heated gross floor area per year, depending on the weather year as well as the numbers and types of flexible buildings. Most of the savings were thanks to dedicated storage assets like domestic hot water storage tanks or batteries instead of the thermal mass of the building envelope.

Harnessing the BEF of all the modelled 650 000 electrically heated residential buildings in Finland yielded annual system cost savings between 20–40 M€ depending on the weather year. This only amounts to around 0.18–0.36 €/m2 of heated gross floor area per year. Uncoordinated BEF resulted in even lower savings, and could incur additional costs during particularly challenging weather years. These observations raise questions about the economic viability of widespread BEF.

All savings from BEF increased with electricity price volatility when more VRE was added to the modelled energy system. Conversely, energy efficiency refurbishments only slightly reduced BEF benefits. Refurbishments could achieve savings ten times larger than BEF, but a fair comparison would require considering respective investment costs.

Overall, the used archetype building modelling approach proved practical for depicting widespread BEF within large-scale energy system optimization frameworks. Future improvements to the presented approach could permit BEF investment planning. Focusing on assets with dedicated storage is recommended thanks to their comparatively larger benefits and ease of modelling. Similarly, multiple weather years should always be considered when analysing BEF benefits to minimize the risk of skewing the results.
Original languageEnglish
QualificationDoctor Degree
Awarding Institution
  • Aalto University
Supervisors/Advisors
  • Lund, Peter D., Supervisor, External person
  • Kiviluoma, Juha, Advisor
Award date31 Dec 2026
Place of PublicationHelsinki
Publisher
Print ISBNs978-952-64-3449-0
Electronic ISBNs978-952-64-3448-3
Publication statusAccepted/In press - 21 Sept 2026
MoE publication typeG5 Doctoral dissertation (article)

Funding

My doctoral studies were primarily funded by the Research Council of Finland project FlexiB (332421), while also benefiting from projects like the Research Council of Finland VaGe (284973), EU Horizon 2020 RealValue (646116) and Spine (774629), as well as Horizon Europe Mopo (101095998). Huge thanks to Adj. Prof. Jean-Nicolas Louis for securing me some VTT funding to help wrap this thesis up.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  2. SDG 11 - Sustainable Cities and Communities
    SDG 11 Sustainable Cities and Communities
  3. SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production
  4. SDG 13 - Climate Action
    SDG 13 Climate Action

Keywords

  • energy system optimization
  • unit commitment
  • economic dispatch
  • energy flexibility
  • demand response
  • space heating
  • water heating
  • space cooling

Fingerprint

Dive into the research topics of 'Integrating residential heating and cooling flexibility into operational energy system optimization'. Together they form a unique fingerprint.

Cite this