Abstract
A commissioning and laboratory tests of an active magnetic bearing supported PM 3kW blower are presented. The motor operation is evaluated in no-load and load tests. An identification of AMB-rotor system, testing of H ∞ centralized control and mass-flow of the blower for recirculation of anode gas in a SOFC are discussed. The key results include comparison between analytical and measured values of an output sensitivity function of different MIMO controllers, measured efficiency and output motor power, and blower measurements.
Original language | English |
---|---|
Title of host publication | 2013 15th European Conference on Power Electronics and Applications, EPE 2013 |
DOIs | |
Publication status | Published - 17 Dec 2013 |
MoE publication type | A4 Article in a conference publication |
Event | 15th European Conference on Power Electronics and Applications, EPE 2013 - Lille, France Duration: 2 Sept 2013 → 6 Sept 2013 |
Conference
Conference | 15th European Conference on Power Electronics and Applications, EPE 2013 |
---|---|
Country/Territory | France |
City | Lille |
Period | 2/09/13 → 6/09/13 |
Keywords
- Alternative energy
- Control methods for electrical systems
- Fuel cell system
- Magnetic bearings
- Magnetic levitation
- MIMO control
- Prototype commissioning