Lap shear tests of bolted and screwed ferritic stainless steel connections

Asko Talja (Corresponding Author), Matjaz Torkar

Research output: Contribution to journalArticleScientificpeer-review

15 Citations (Scopus)

Abstract

The development of design guidance for stainless steel structures requires more tests on ferritic grade connections. This paper deals with a series of lap shear tests which have been carried out on various configurations of bolted and screwed connections. The tests demonstrate net section failure, bearing failure and block tearing failure. The material is a ferritic stainless steel of grade 1.4509 (AISI 441) with a thickness of 0.5-4.5 mm. The results are utilized in developing design guidance in accordance with Eurocodes
Original languageEnglish
Pages (from-to)157-168
JournalThin-Walled Structures
Volume83
DOIs
Publication statusPublished - 2014
MoE publication typeA1 Journal article-refereed

Keywords

  • stainless steel
  • ferritic
  • shear connection
  • resistance
  • design
  • testing

Fingerprint

Dive into the research topics of 'Lap shear tests of bolted and screwed ferritic stainless steel connections'. Together they form a unique fingerprint.