Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute

Markku Rantanen, Sari Saxholm, Irina V. Sadkovskaya, Aleksey I. Eikhvald

    Research output: Book/ReportReport

    Abstract

    The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.
    Original languageEnglish
    Place of PublicationEspoo
    PublisherCentre of Metrology and Accreditation
    Number of pages24
    ISBN (Print)978-952-5610-60-4
    Publication statusPublished - 2010
    MoE publication typeD4 Published development or research report or study

    Publication series

    SeriesMIKES Publication
    NumberJ1/2010
    ISSN1235-5704

    Fingerprint

    low pressure
    manometers
    diaphragms
    metrology
    capacitance
    pistons
    oils
    lasers

    Keywords

    • interlaboratory comparison
    • absolute pressures

    Cite this

    Rantanen, M., Saxholm, S., Sadkovskaya, I. V., & Eikhvald, A. I. (2010). Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute. Espoo: Centre of Metrology and Accreditation. MIKES Publication, No. J1/2010
    Rantanen, Markku ; Saxholm, Sari ; Sadkovskaya, Irina V. ; Eikhvald, Aleksey I. / Low pressure comparison between MIKES and VNIIM : Range 1 Pa to 1000 Pa absolute. Espoo : Centre of Metrology and Accreditation, 2010. 24 p. (MIKES Publication; No. J1/2010).
    @book{b2345dc157564b28af047f2dc5935b67,
    title = "Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute",
    abstract = "The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.",
    keywords = "interlaboratory comparison, absolute pressures",
    author = "Markku Rantanen and Sari Saxholm and Sadkovskaya, {Irina V.} and Eikhvald, {Aleksey I.}",
    year = "2010",
    language = "English",
    isbn = "978-952-5610-60-4",
    series = "MIKES Publication",
    publisher = "Centre of Metrology and Accreditation",
    number = "J1/2010",
    address = "Finland",

    }

    Rantanen, M, Saxholm, S, Sadkovskaya, IV & Eikhvald, AI 2010, Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute. MIKES Publication, no. J1/2010, Centre of Metrology and Accreditation, Espoo.

    Low pressure comparison between MIKES and VNIIM : Range 1 Pa to 1000 Pa absolute. / Rantanen, Markku; Saxholm, Sari; Sadkovskaya, Irina V.; Eikhvald, Aleksey I.

    Espoo : Centre of Metrology and Accreditation, 2010. 24 p. (MIKES Publication; No. J1/2010).

    Research output: Book/ReportReport

    TY - BOOK

    T1 - Low pressure comparison between MIKES and VNIIM

    T2 - Range 1 Pa to 1000 Pa absolute

    AU - Rantanen, Markku

    AU - Saxholm, Sari

    AU - Sadkovskaya, Irina V.

    AU - Eikhvald, Aleksey I.

    PY - 2010

    Y1 - 2010

    N2 - The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.

    AB - The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.

    KW - interlaboratory comparison

    KW - absolute pressures

    M3 - Report

    SN - 978-952-5610-60-4

    T3 - MIKES Publication

    BT - Low pressure comparison between MIKES and VNIIM

    PB - Centre of Metrology and Accreditation

    CY - Espoo

    ER -

    Rantanen M, Saxholm S, Sadkovskaya IV, Eikhvald AI. Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute. Espoo: Centre of Metrology and Accreditation, 2010. 24 p. (MIKES Publication; No. J1/2010).