Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute

Markku Rantanen, Sari Saxholm, Irina V. Sadkovskaya, Aleksey I. Eikhvald

Research output: Book/ReportReport

Abstract

The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.
Original languageEnglish
Place of PublicationEspoo
PublisherCentre of Metrology and Accreditation
Number of pages24
ISBN (Print)978-952-5610-60-4
Publication statusPublished - 2010
MoE publication typeD4 Published development or research report or study

Publication series

SeriesMIKES Publication
NumberJ1/2010
ISSN1235-5704

Fingerprint

low pressure
manometers
diaphragms
metrology
capacitance
pistons
oils
lasers

Keywords

  • interlaboratory comparison
  • absolute pressures

Cite this

Rantanen, M., Saxholm, S., Sadkovskaya, I. V., & Eikhvald, A. I. (2010). Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute. Espoo: Centre of Metrology and Accreditation. MIKES Publication, No. J1/2010
Rantanen, Markku ; Saxholm, Sari ; Sadkovskaya, Irina V. ; Eikhvald, Aleksey I. / Low pressure comparison between MIKES and VNIIM : Range 1 Pa to 1000 Pa absolute. Espoo : Centre of Metrology and Accreditation, 2010. 24 p. (MIKES Publication; No. J1/2010).
@book{b2345dc157564b28af047f2dc5935b67,
title = "Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute",
abstract = "The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.",
keywords = "interlaboratory comparison, absolute pressures",
author = "Markku Rantanen and Sari Saxholm and Sadkovskaya, {Irina V.} and Eikhvald, {Aleksey I.}",
year = "2010",
language = "English",
isbn = "978-952-5610-60-4",
series = "MIKES Publication",
publisher = "Centre of Metrology and Accreditation",
number = "J1/2010",
address = "Finland",

}

Rantanen, M, Saxholm, S, Sadkovskaya, IV & Eikhvald, AI 2010, Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute. MIKES Publication, no. J1/2010, Centre of Metrology and Accreditation, Espoo.

Low pressure comparison between MIKES and VNIIM : Range 1 Pa to 1000 Pa absolute. / Rantanen, Markku; Saxholm, Sari; Sadkovskaya, Irina V.; Eikhvald, Aleksey I.

Espoo : Centre of Metrology and Accreditation, 2010. 24 p. (MIKES Publication; No. J1/2010).

Research output: Book/ReportReport

TY - BOOK

T1 - Low pressure comparison between MIKES and VNIIM

T2 - Range 1 Pa to 1000 Pa absolute

AU - Rantanen, Markku

AU - Saxholm, Sari

AU - Sadkovskaya, Irina V.

AU - Eikhvald, Aleksey I.

PY - 2010

Y1 - 2010

N2 - The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.

AB - The pressure laboratories of Centre for Metrology and Accreditation (MIKES) and D. I. Mendeleyev All-Russian Institute for Metrology (VNIIM) compared their low absolute pressures in the range 1 Pa to 1000 Pa in April and May 2010. VNIIM has during the recent years developed a new primary standard for low pressures, a laser interferometric oil manometer (LIOM) which is based on the U-tube principle. At MIKES the standards in the compared pressure range are commercial secondary standards, a 130 Pa capacitance diaphragm gauge traceable to PTB, Berlin, and a piston manometer FPG8601. The standards of MIKES are capable of relatively low uncertainties even though they are secondary ones. The transfer standard was a capacitance diaphragm gauge MKS Baratron 698A for the range 0-1000 Pa differential, equipped with a signal conditioner MKS 670B. The agreement of the results from MIKES and VNIIM was good.

KW - interlaboratory comparison

KW - absolute pressures

M3 - Report

SN - 978-952-5610-60-4

T3 - MIKES Publication

BT - Low pressure comparison between MIKES and VNIIM

PB - Centre of Metrology and Accreditation

CY - Espoo

ER -

Rantanen M, Saxholm S, Sadkovskaya IV, Eikhvald AI. Low pressure comparison between MIKES and VNIIM: Range 1 Pa to 1000 Pa absolute. Espoo: Centre of Metrology and Accreditation, 2010. 24 p. (MIKES Publication; No. J1/2010).