Luminous efficacy measurement of solid-state lamps

Tuomas Poikonen, Tomi Pulli, Anna Vaskuri, Hans Baumgartner, Petri Kärhä, Erkki Ikonen

Research output: Contribution to journalArticleScientificpeer-review

10 Citations (Scopus)

Abstract

We present a system for luminous efficacy measurements of solid-state lamps (SSLs). It is based on a 1.65 m integrating sphere, originally designed for luminous flux measurements of dc-operated incandescent standard lamps. The sphere was slightly modified, and equipped with a programmable ac-power supply, as well as equipment for electrical power measurement of the lamps. The waveforms of both the electrical power and the luminous flux can be measured for analysing the quality of the electronics and the light produced by the SSLs. A goniospectrometer is used for angular characterization of the lamp intensity. Luminous efficacy test measurements were conducted for a group of 25 SSLs of different types. Special attention was paid to the spectral, spatial and self-absorption corrections to obtain low measurement uncertainty. The luminous efficacies were between 25 lm W−1 and 64 lm W−1, and the total harmonic distortions of the current waveforms were in the range of 30% to 280%. Depending on the lamp, the maximum deviation of the flux from its mean value was 0.06% to 105%. The relative expanded uncertainty obtainable for the luminous efficacy of a typical SSL with stable built-in electronics is 1.2% (k = 2).
Original languageEnglish
Pages (from-to)135-140
Number of pages5
JournalMetrologia
Volume49
Issue number2
DOIs
Publication statusPublished - 2012
MoE publication typeA1 Journal article-refereed

Fingerprint

Electric lamps
Fluxes
Electronic equipment
Harmonic distortion

Keywords

  • solid-state lamps

Cite this

Poikonen, T., Pulli, T., Vaskuri, A., Baumgartner, H., Kärhä, P., & Ikonen, E. (2012). Luminous efficacy measurement of solid-state lamps. Metrologia, 49(2), 135-140. https://doi.org/10.1088/0026-1394/49/2/S135
Poikonen, Tuomas ; Pulli, Tomi ; Vaskuri, Anna ; Baumgartner, Hans ; Kärhä, Petri ; Ikonen, Erkki. / Luminous efficacy measurement of solid-state lamps. In: Metrologia. 2012 ; Vol. 49, No. 2. pp. 135-140.
@article{ae243362082449a387d5737f5733a45a,
title = "Luminous efficacy measurement of solid-state lamps",
abstract = "We present a system for luminous efficacy measurements of solid-state lamps (SSLs). It is based on a 1.65 m integrating sphere, originally designed for luminous flux measurements of dc-operated incandescent standard lamps. The sphere was slightly modified, and equipped with a programmable ac-power supply, as well as equipment for electrical power measurement of the lamps. The waveforms of both the electrical power and the luminous flux can be measured for analysing the quality of the electronics and the light produced by the SSLs. A goniospectrometer is used for angular characterization of the lamp intensity. Luminous efficacy test measurements were conducted for a group of 25 SSLs of different types. Special attention was paid to the spectral, spatial and self-absorption corrections to obtain low measurement uncertainty. The luminous efficacies were between 25 lm W−1 and 64 lm W−1, and the total harmonic distortions of the current waveforms were in the range of 30{\%} to 280{\%}. Depending on the lamp, the maximum deviation of the flux from its mean value was 0.06{\%} to 105{\%}. The relative expanded uncertainty obtainable for the luminous efficacy of a typical SSL with stable built-in electronics is 1.2{\%} (k = 2).",
keywords = "solid-state lamps",
author = "Tuomas Poikonen and Tomi Pulli and Anna Vaskuri and Hans Baumgartner and Petri K{\"a}rh{\"a} and Erkki Ikonen",
year = "2012",
doi = "10.1088/0026-1394/49/2/S135",
language = "English",
volume = "49",
pages = "135--140",
journal = "Metrologia",
issn = "0026-1394",
publisher = "Institute of Physics IOP",
number = "2",

}

Poikonen, T, Pulli, T, Vaskuri, A, Baumgartner, H, Kärhä, P & Ikonen, E 2012, 'Luminous efficacy measurement of solid-state lamps', Metrologia, vol. 49, no. 2, pp. 135-140. https://doi.org/10.1088/0026-1394/49/2/S135

Luminous efficacy measurement of solid-state lamps. / Poikonen, Tuomas; Pulli, Tomi; Vaskuri, Anna; Baumgartner, Hans; Kärhä, Petri; Ikonen, Erkki.

In: Metrologia, Vol. 49, No. 2, 2012, p. 135-140.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - Luminous efficacy measurement of solid-state lamps

AU - Poikonen, Tuomas

AU - Pulli, Tomi

AU - Vaskuri, Anna

AU - Baumgartner, Hans

AU - Kärhä, Petri

AU - Ikonen, Erkki

PY - 2012

Y1 - 2012

N2 - We present a system for luminous efficacy measurements of solid-state lamps (SSLs). It is based on a 1.65 m integrating sphere, originally designed for luminous flux measurements of dc-operated incandescent standard lamps. The sphere was slightly modified, and equipped with a programmable ac-power supply, as well as equipment for electrical power measurement of the lamps. The waveforms of both the electrical power and the luminous flux can be measured for analysing the quality of the electronics and the light produced by the SSLs. A goniospectrometer is used for angular characterization of the lamp intensity. Luminous efficacy test measurements were conducted for a group of 25 SSLs of different types. Special attention was paid to the spectral, spatial and self-absorption corrections to obtain low measurement uncertainty. The luminous efficacies were between 25 lm W−1 and 64 lm W−1, and the total harmonic distortions of the current waveforms were in the range of 30% to 280%. Depending on the lamp, the maximum deviation of the flux from its mean value was 0.06% to 105%. The relative expanded uncertainty obtainable for the luminous efficacy of a typical SSL with stable built-in electronics is 1.2% (k = 2).

AB - We present a system for luminous efficacy measurements of solid-state lamps (SSLs). It is based on a 1.65 m integrating sphere, originally designed for luminous flux measurements of dc-operated incandescent standard lamps. The sphere was slightly modified, and equipped with a programmable ac-power supply, as well as equipment for electrical power measurement of the lamps. The waveforms of both the electrical power and the luminous flux can be measured for analysing the quality of the electronics and the light produced by the SSLs. A goniospectrometer is used for angular characterization of the lamp intensity. Luminous efficacy test measurements were conducted for a group of 25 SSLs of different types. Special attention was paid to the spectral, spatial and self-absorption corrections to obtain low measurement uncertainty. The luminous efficacies were between 25 lm W−1 and 64 lm W−1, and the total harmonic distortions of the current waveforms were in the range of 30% to 280%. Depending on the lamp, the maximum deviation of the flux from its mean value was 0.06% to 105%. The relative expanded uncertainty obtainable for the luminous efficacy of a typical SSL with stable built-in electronics is 1.2% (k = 2).

KW - solid-state lamps

U2 - 10.1088/0026-1394/49/2/S135

DO - 10.1088/0026-1394/49/2/S135

M3 - Article

VL - 49

SP - 135

EP - 140

JO - Metrologia

JF - Metrologia

SN - 0026-1394

IS - 2

ER -

Poikonen T, Pulli T, Vaskuri A, Baumgartner H, Kärhä P, Ikonen E. Luminous efficacy measurement of solid-state lamps. Metrologia. 2012;49(2):135-140. https://doi.org/10.1088/0026-1394/49/2/S135