Methods for comparison of loss angle standards at 10 kV level

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

Abstract

Comparison of loss angle measurements and measurement techniques at power frequency up to 10 kV are presented. The loss angle standards developed by VNIIM are based on low loss ceramic capacitors with a detachable loss resistor in series with it. The tand values of the studied standards ranged from - 1.10 -4 to 1000.10 -4. The loss angle standards were characterized using established references at VNIIM and MIKES.

Original languageEnglish
Title of host publication2012 Conference on Precision electromagnetic Measurements
PublisherIEEE Institute of Electrical and Electronic Engineers
Pages402-403
Number of pages2
ISBN (Electronic)978-1-4673-0442-9
ISBN (Print)978-1-4673-0439-9
DOIs
Publication statusPublished - 3 Oct 2012
MoE publication typeA4 Article in a conference publication
Event2012 Conference on Precision Electromagnetic Measurements, CPEM 2012 - Washington, DC, United States
Duration: 1 Jul 20126 Jul 2012

Conference

Conference2012 Conference on Precision Electromagnetic Measurements, CPEM 2012
CountryUnited States
CityWashington, DC
Period1/07/126/07/12

Fingerprint

Ceramic capacitors
Angle measurement
resistors
Resistors
capacitors
ceramics

Keywords

  • Capacitance
  • high-voltage techniques
  • loss measurement
  • measurement standards
  • uncertainty

Cite this

Hällström, J., Klionsky, M., & Suomalainen, E. P. (2012). Methods for comparison of loss angle standards at 10 kV level. In 2012 Conference on Precision electromagnetic Measurements (pp. 402-403). [6250973] IEEE Institute of Electrical and Electronic Engineers . https://doi.org/10.1109/CPEM.2012.6250973
Hällström, J. ; Klionsky, M. ; Suomalainen, E. P. / Methods for comparison of loss angle standards at 10 kV level. 2012 Conference on Precision electromagnetic Measurements. IEEE Institute of Electrical and Electronic Engineers , 2012. pp. 402-403
@inproceedings{30ad45f941d84d1d8f6ab31d0a62bb00,
title = "Methods for comparison of loss angle standards at 10 kV level",
abstract = "Comparison of loss angle measurements and measurement techniques at power frequency up to 10 kV are presented. The loss angle standards developed by VNIIM are based on low loss ceramic capacitors with a detachable loss resistor in series with it. The tand values of the studied standards ranged from - 1.10 -4 to 1000.10 -4. The loss angle standards were characterized using established references at VNIIM and MIKES.",
keywords = "Capacitance, high-voltage techniques, loss measurement, measurement standards, uncertainty",
author = "J. H{\"a}llstr{\"o}m and M. Klionsky and Suomalainen, {E. P.}",
year = "2012",
month = "10",
day = "3",
doi = "10.1109/CPEM.2012.6250973",
language = "English",
isbn = "978-1-4673-0439-9",
pages = "402--403",
booktitle = "2012 Conference on Precision electromagnetic Measurements",
publisher = "IEEE Institute of Electrical and Electronic Engineers",
address = "United States",

}

Hällström, J, Klionsky, M & Suomalainen, EP 2012, Methods for comparison of loss angle standards at 10 kV level. in 2012 Conference on Precision electromagnetic Measurements., 6250973, IEEE Institute of Electrical and Electronic Engineers , pp. 402-403, 2012 Conference on Precision Electromagnetic Measurements, CPEM 2012, Washington, DC, United States, 1/07/12. https://doi.org/10.1109/CPEM.2012.6250973

Methods for comparison of loss angle standards at 10 kV level. / Hällström, J.; Klionsky, M.; Suomalainen, E. P.

2012 Conference on Precision electromagnetic Measurements. IEEE Institute of Electrical and Electronic Engineers , 2012. p. 402-403 6250973.

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

TY - GEN

T1 - Methods for comparison of loss angle standards at 10 kV level

AU - Hällström, J.

AU - Klionsky, M.

AU - Suomalainen, E. P.

PY - 2012/10/3

Y1 - 2012/10/3

N2 - Comparison of loss angle measurements and measurement techniques at power frequency up to 10 kV are presented. The loss angle standards developed by VNIIM are based on low loss ceramic capacitors with a detachable loss resistor in series with it. The tand values of the studied standards ranged from - 1.10 -4 to 1000.10 -4. The loss angle standards were characterized using established references at VNIIM and MIKES.

AB - Comparison of loss angle measurements and measurement techniques at power frequency up to 10 kV are presented. The loss angle standards developed by VNIIM are based on low loss ceramic capacitors with a detachable loss resistor in series with it. The tand values of the studied standards ranged from - 1.10 -4 to 1000.10 -4. The loss angle standards were characterized using established references at VNIIM and MIKES.

KW - Capacitance

KW - high-voltage techniques

KW - loss measurement

KW - measurement standards

KW - uncertainty

UR - http://www.scopus.com/inward/record.url?scp=84866788268&partnerID=8YFLogxK

U2 - 10.1109/CPEM.2012.6250973

DO - 10.1109/CPEM.2012.6250973

M3 - Conference article in proceedings

AN - SCOPUS:84866788268

SN - 978-1-4673-0439-9

SP - 402

EP - 403

BT - 2012 Conference on Precision electromagnetic Measurements

PB - IEEE Institute of Electrical and Electronic Engineers

ER -

Hällström J, Klionsky M, Suomalainen EP. Methods for comparison of loss angle standards at 10 kV level. In 2012 Conference on Precision electromagnetic Measurements. IEEE Institute of Electrical and Electronic Engineers . 2012. p. 402-403. 6250973 https://doi.org/10.1109/CPEM.2012.6250973