Abstract
Comparison of loss angle measurements and measurement techniques at power frequency up to 10 kV are presented. The loss angle standards developed by VNIIM are based on low loss ceramic capacitors with a detachable loss resistor in series with it. The tand values of the studied standards ranged from - 1.10 -4 to 1000.10 -4. The loss angle standards were characterized using established references at VNIIM and MIKES.
Original language | English |
---|---|
Title of host publication | 2012 Conference on Precision electromagnetic Measurements |
Publisher | IEEE Institute of Electrical and Electronic Engineers |
Pages | 402-403 |
Number of pages | 2 |
ISBN (Electronic) | 978-1-4673-0442-9 |
ISBN (Print) | 978-1-4673-0439-9 |
DOIs | |
Publication status | Published - 3 Oct 2012 |
MoE publication type | A4 Article in a conference publication |
Event | 2012 Conference on Precision Electromagnetic Measurements, CPEM 2012 - Washington, DC, United States Duration: 1 Jul 2012 → 6 Jul 2012 |
Conference
Conference | 2012 Conference on Precision Electromagnetic Measurements, CPEM 2012 |
---|---|
Abbreviated title | CPEM |
Country/Territory | United States |
City | Washington, DC |
Period | 1/07/12 → 6/07/12 |
Keywords
- Capacitance
- high-voltage techniques
- loss measurement
- measurement standards
- uncertainty