Microneedle based sampling for lipid analysis

Research output: Contribution to conferenceOther conference contributionScientificpeer-review

Abstract

We have developed a microneedle based sample collecting system that is capable of extracting lipid samples from an artificial lipid layer on a microscope slide. Such a system can be used in the future to collect lipid samples from real tissue sections and help surgeons in their decision making during surgical operations. The sample collection system consists of a silicon based multiport microneedle integrated with polymer microfluidics. A special micromanipulator system is developed to control the positioning of the needle and the sampling event. Mass spectrometry analysis is used to show that the lipid extraction from a standard lipid sample can be successfully done.
Original languageEnglish
Number of pages4
Publication statusPublished - 2014
MoE publication typeNot Eligible
Event10th Micronano System Workshop, MSW 2014 - Uppsala, Sweden
Duration: 15 May 201416 May 2014

Conference

Conference10th Micronano System Workshop, MSW 2014
Abbreviated titleMSW 2014
CountrySweden
CityUppsala
Period15/05/1416/05/14

Fingerprint

Sampling
Lipids
Micromanipulators
Silicon
Microfluidics
Needles
Mass spectrometry
Polymers
Microscopes
Decision making
Tissue

Cite this

Hokkanen, A., Stuns, I., Schmid, P., Kokkonen, A., Steinecker, A., Heimala, P., & Hakalahti, L. (2014). Microneedle based sampling for lipid analysis. 10th Micronano System Workshop, MSW 2014, Uppsala, Sweden.
Hokkanen, Ari ; Stuns, Ingmar ; Schmid, P. ; Kokkonen, Annukka ; Steinecker, A. ; Heimala, Päivi ; Hakalahti, Leena. / Microneedle based sampling for lipid analysis. 10th Micronano System Workshop, MSW 2014, Uppsala, Sweden.4 p.
@conference{7af62edfca2c4356bd52ff2d291a7dd9,
title = "Microneedle based sampling for lipid analysis",
abstract = "We have developed a microneedle based sample collecting system that is capable of extracting lipid samples from an artificial lipid layer on a microscope slide. Such a system can be used in the future to collect lipid samples from real tissue sections and help surgeons in their decision making during surgical operations. The sample collection system consists of a silicon based multiport microneedle integrated with polymer microfluidics. A special micromanipulator system is developed to control the positioning of the needle and the sampling event. Mass spectrometry analysis is used to show that the lipid extraction from a standard lipid sample can be successfully done.",
author = "Ari Hokkanen and Ingmar Stuns and P. Schmid and Annukka Kokkonen and A. Steinecker and P{\"a}ivi Heimala and Leena Hakalahti",
note = "HUO: Oral presentation ; 10th Micronano System Workshop, MSW 2014, MSW 2014 ; Conference date: 15-05-2014 Through 16-05-2014",
year = "2014",
language = "English",

}

Hokkanen, A, Stuns, I, Schmid, P, Kokkonen, A, Steinecker, A, Heimala, P & Hakalahti, L 2014, 'Microneedle based sampling for lipid analysis' 10th Micronano System Workshop, MSW 2014, Uppsala, Sweden, 15/05/14 - 16/05/14, .

Microneedle based sampling for lipid analysis. / Hokkanen, Ari; Stuns, Ingmar; Schmid, P.; Kokkonen, Annukka; Steinecker, A.; Heimala, Päivi; Hakalahti, Leena.

2014. 10th Micronano System Workshop, MSW 2014, Uppsala, Sweden.

Research output: Contribution to conferenceOther conference contributionScientificpeer-review

TY - CONF

T1 - Microneedle based sampling for lipid analysis

AU - Hokkanen, Ari

AU - Stuns, Ingmar

AU - Schmid, P.

AU - Kokkonen, Annukka

AU - Steinecker, A.

AU - Heimala, Päivi

AU - Hakalahti, Leena

N1 - HUO: Oral presentation

PY - 2014

Y1 - 2014

N2 - We have developed a microneedle based sample collecting system that is capable of extracting lipid samples from an artificial lipid layer on a microscope slide. Such a system can be used in the future to collect lipid samples from real tissue sections and help surgeons in their decision making during surgical operations. The sample collection system consists of a silicon based multiport microneedle integrated with polymer microfluidics. A special micromanipulator system is developed to control the positioning of the needle and the sampling event. Mass spectrometry analysis is used to show that the lipid extraction from a standard lipid sample can be successfully done.

AB - We have developed a microneedle based sample collecting system that is capable of extracting lipid samples from an artificial lipid layer on a microscope slide. Such a system can be used in the future to collect lipid samples from real tissue sections and help surgeons in their decision making during surgical operations. The sample collection system consists of a silicon based multiport microneedle integrated with polymer microfluidics. A special micromanipulator system is developed to control the positioning of the needle and the sampling event. Mass spectrometry analysis is used to show that the lipid extraction from a standard lipid sample can be successfully done.

M3 - Other conference contribution

ER -

Hokkanen A, Stuns I, Schmid P, Kokkonen A, Steinecker A, Heimala P et al. Microneedle based sampling for lipid analysis. 2014. 10th Micronano System Workshop, MSW 2014, Uppsala, Sweden.