Abstract
Model for the electroless nickel plating of through holes board process developed earlier is tested in this paper on independent (from calibration) data and shown to be adequate and thus capable to be applied for monitoring of the board and bath parameters usually analysed in laboratory with a delay of 6-10 hours.
Original language | English |
---|---|
Title of host publication | Proceedings of the Fifth IASTED International Conference on Modelling, Simulation, and Optimization |
Publisher | Acta Press |
Pages | 74-84 |
ISBN (Print) | 0-88986-524-8, 978-0-88986-526-6 |
Publication status | Published - 2005 |
MoE publication type | A4 Article in a conference publication |
Event | 5th IASTED International Conference on Modelling, Simulation, and Optimization - Oranjestad, Aruba Duration: 29 Aug 2005 → 31 Aug 2005 |
Conference
Conference | 5th IASTED International Conference on Modelling, Simulation, and Optimization |
---|---|
Country/Territory | Aruba |
City | Oranjestad |
Period | 29/08/05 → 31/08/05 |
Keywords
- Chemical plating
- Identification
- Modelling