Multipurpose RTOF Fourier diffractometer at the ET-RR-1 reactor

R. Maayouf, Antero Tiitta

Research output: Book/ReportReport

Abstract

The present work represents a further study of the basic RTOF Fourier multipurpose diffractometer, to start with, at the ET RR 1 reactor. The functions of the suggested arrangement are thoroughly discussed and the possibilities of its expansion are also assessed. The flexibility of the suggested arrangement allows its further expansion both for stress measurements at 90o scattering angle with two detector banks at opposite sides of the incident beam and for operation in the transmission diffraction mode.
Original languageEnglish
Place of PublicationEspoo
PublisherVTT Technical Research Centre of Finland
Number of pages18
ISBN (Print)951-38-4436-6
Publication statusPublished - 1993
MoE publication typeNot Eligible

Publication series

SeriesVTT Tiedotteita - Meddelanden - Research Notes
Number1502
ISSN1235-0605

Keywords

  • time-of-flight spectrometers
  • neutrons
  • slow neutrons
  • scattering
  • beam pulsers
  • neutron diffractometers

Fingerprint