New AC current shunts of MIKES

Tapio Mansten, Anssi Rautiainen, Panu Helistö

    Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientific

    4 Citations (Scopus)

    Abstract

    A new construction principle of AC current shunts has been applied to a set of shunts for AC currents from 1 A to 20 A, 20 Hz-10 kHz. The completed set will also cover current ranges from 20 mA to 1 A. The shunts are stable and do not show excessive AC-DC amplitude or phase differences and can thus be calibrated to work as AC current and resistance reference standards up to 10 kHz.
    Original languageEnglish
    Title of host publication2002 Conference on Precision Electromagnetic Measurements Conference Digest
    PublisherIEEE Institute of Electrical and Electronic Engineers
    Pages370-371
    ISBN (Print)0-7803-7242-5
    DOIs
    Publication statusPublished - 2002
    MoE publication typeB3 Non-refereed article in conference proceedings
    EventConference on Precision Electromagnetic Measurements, CPEM 2002 - Ottawa, Canada
    Duration: 16 Jun 200221 Jun 2002

    Conference

    ConferenceConference on Precision Electromagnetic Measurements, CPEM 2002
    CountryCanada
    CityOttawa
    Period16/06/0221/06/02

    Fingerprint Dive into the research topics of 'New AC current shunts of MIKES'. Together they form a unique fingerprint.

  • Cite this

    Mansten, T., Rautiainen, A., & Helistö, P. (2002). New AC current shunts of MIKES. In 2002 Conference on Precision Electromagnetic Measurements Conference Digest (pp. 370-371). [WeP41] IEEE Institute of Electrical and Electronic Engineers. https://doi.org/10.1109/CPEM.2002.1034876