TY - JOUR
T1 - Performance Analysis of Bus Voltage in Distribution Network with High Penetration of PV Controlled via Data-Driven Approach
AU - Yadav, Anju
AU - Kishor, Nand
AU - Negi, Richa
AU - Opas, Mikael
AU - Raussi, Petra
N1 - Publisher Copyright:
© 2023 Anju Yadav et al.
PY - 2023
Y1 - 2023
N2 - Integration of large-scale distributed photovoltaic (PV) generation resources can lead to technical challenges, particularly voltage rise caused by PVs power injection at the time of high solar radiation profile and low load demand. Reactive power control of PV inverters can help mitigate the voltage rise, which arises just for a short duration due to high incident solar radiation. There is a possibility to control functions on these PV inverters based on the rating of the PV inverter. For one-second resolution, local data-driven voltage sensitivity estimation is applied to update the control functions such as volt-var and volt-watt on the PV inverters so as to regulate the bus voltage. Different forms of solar radiation profiles, transient varying, smooth varying, and worst operating scenario corresponding to the minimum load at the time of high PV generation, are included. The study is demonstrated for different PV penetration levels. The voltage analysis on buses is performed using power hardware (PV emulator) in the loop simulation, at one of the buses in the network, while the remaining PVs are being controlled using volt-var control (VVC)/volt-watt control (VWC) methods. The applied approach confirms to maintaining bus voltage within limits even against a very short transient time instant of solar radiation profile.
AB - Integration of large-scale distributed photovoltaic (PV) generation resources can lead to technical challenges, particularly voltage rise caused by PVs power injection at the time of high solar radiation profile and low load demand. Reactive power control of PV inverters can help mitigate the voltage rise, which arises just for a short duration due to high incident solar radiation. There is a possibility to control functions on these PV inverters based on the rating of the PV inverter. For one-second resolution, local data-driven voltage sensitivity estimation is applied to update the control functions such as volt-var and volt-watt on the PV inverters so as to regulate the bus voltage. Different forms of solar radiation profiles, transient varying, smooth varying, and worst operating scenario corresponding to the minimum load at the time of high PV generation, are included. The study is demonstrated for different PV penetration levels. The voltage analysis on buses is performed using power hardware (PV emulator) in the loop simulation, at one of the buses in the network, while the remaining PVs are being controlled using volt-var control (VVC)/volt-watt control (VWC) methods. The applied approach confirms to maintaining bus voltage within limits even against a very short transient time instant of solar radiation profile.
UR - http://www.scopus.com/inward/record.url?scp=85174490020&partnerID=8YFLogxK
U2 - 10.1155/2023/3708751
DO - 10.1155/2023/3708751
M3 - Article
AN - SCOPUS:85174490020
SN - 2050-7038
VL - 2023
JO - International Transactions on Electrical Energy Systems
JF - International Transactions on Electrical Energy Systems
M1 - 3708751
ER -