Skip to main navigation Skip to search Skip to main content

Portable emissions toxicity system: Evaluating the toxicity of emissions or polluted air by exposure of cell cultures at air-liquid interface in a compact field-deployable setup

  • Michal Vojtisek-Lom*
  • , Lubos Dittrich
  • , Martin Pechout
  • , Tereza Cervena
  • , Anezka Vimrova
  • , Jitka Sikorova
  • , Tana Zavodna
  • , Jakub Ondracek
  • , Päivi Aakko-Saksa
  • , Jan Topinka
  • , Pavel Rössner
  • *Corresponding author for this work
    • Technical University of Liberec (TUL)
    • Czech University of Life Sciences Prague (CULS)
    • Czech Academy of Sciences

    Research output: Contribution to journal › Article › Scientific › peer-review

    Abstract

    Exposure of cell cultures at air-liquid interface (ALI), mimicking i.e. human lung surface, is believed to be one of the most realistic means to model toxicity of complex mixtures of pollutants on human health. The complexity of the close cooperation of “emissions source” and toxicology groups and of the instrumentation are among the limiting factors of ALI. In this work, the concepts of ALI exposure and real-world emissions monitoring using portable emissions monitoring systems (PEMS) are combined into a portable emissions or air toxicity system, for field deployment, including operation in moving vehicles. Cell cultures grown on 6 mm inserts are placed in an airtight 17x13x9 cm exposure box, where the sample is symmetrically distributed into 8 wells of a standard Transwell 24-well holder at 25 cm3/min/insert. In a 40x35x45 cm inner dimensions incubator, sample and control air are conditioned to 5 % CO2, 37 °C and >85 % humidity and drawn through 2–4 exposure boxes. Characterization with silver nanoparticles revealed 50 % particle losses at 15 nm and deposition rate of approximately 1.5 % at both 10 and 21 nm mean diameter. The system has undergone an extensive field validation, including 4 h of exposure and 2 h transport in a vehicle each day for 5 days, 5-day operation outside in vans and tents at −7 to +32 °C, long transport and test on a heavy-duty truck, during which cells were exposed to the diluted exhaust from the truck, this being the first known use of ALI exposure chamber as PEMS. The portable exposure chamber, along with a field-deployable auxiliary mobile base including a small laminar flow box, additional incubator and freezer, can be easily used to study the toxicity of various emissions, effluents and polluted air, aiming for a more relevant toxicity measure than chemical composition alone.

    Original languageEnglish
    Article number178010
    JournalScience of the Total Environment
    Volume959
    DOIs
    Publication statusPublished - Jan 2025
    MoE publication typeA1 Journal article-refereed

    Funding

    The on-road truck study was part of the PAREMPI project, funded by the European Commission within the Horizon Europe programme, grant no. 101096133. All other parts of this work have been funded by the Czech Science Foundation grant no. 22-10279S: The impact of real-world ambient air pollution exposure on human lung and olfactory cells grown at the air-liquid interface. The particle calibration laboratory and part of the toxicological laboratory instruments, other than the exposure system, were funded by the Czech Ministry of Education large research infrastructure projects no. LM2023030 (ACTRIS-CZ), LM2023066 (NanoEnviCz) and LM2023053 (EATRIS-CZ).

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 3 - Good Health and Well-being
      SDG 3 Good Health and Well-being
    2. SDG 13 - Climate Action
      SDG 13 Climate Action

    Keywords

    • Air-liquid interface
    • Mobile laboratory
    • Mobile sources
    • Polluted air
    • Toxicity

    Fingerprint

    Dive into the research topics of 'Portable emissions toxicity system: Evaluating the toxicity of emissions or polluted air by exposure of cell cultures at air-liquid interface in a compact field-deployable setup'. Together they form a unique fingerprint.

    Cite this