Abstract
This paper describes the setup of sampling-based high voltage measuring systems for reactive compensation components recently developed at VTT and PTB. First measurements show an agreement within 10-4 between both measuring systems. Both a phantom power source emulating reactors and capacitors with adjustable losses, and a set of real reactive components were measured. Measurements were performed with stable 53 Hz frequency and variable 50 Hz power frequency. The measuring systems are developed within the frame of the European project "ELPOW-Metrology for the Electrical Power Industry".
Original language | English |
---|---|
Title of host publication | Precision Electromagnetic Measurements (CPEM 2016), 2016 Conference on |
Publisher | IEEE Institute of Electrical and Electronic Engineers |
Pages | 1-3 |
ISBN (Electronic) | 978-1-4673-9134-4, 978-1-4673-9132-0 |
ISBN (Print) | 978-1-4673-9135-1 |
DOIs | |
Publication status | Published - 11 Aug 2016 |
MoE publication type | A4 Article in a conference publication |
Event | Conference on Precision Electromagnetic Measurements, CPEM 2016 - Ottawa, Canada Duration: 10 Jul 2016 → 15 Jul 2016 |
Conference
Conference | Conference on Precision Electromagnetic Measurements, CPEM 2016 |
---|---|
Abbreviated title | CPEM 2016 |
Country/Territory | Canada |
City | Ottawa |
Period | 10/07/16 → 15/07/16 |
Keywords
- Capacitor Losses
- Loss compensation
- Power Measurements
- Precision Measurements
- Reactor losses
- Uncertainty