Precision loss measurement of reactive compensation components by sampling voltage and current

E. Mohns, Jari Hällström, Esa-Pekka Suomalainen, H. Badura, S. Fricke

    Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

    Abstract

    This paper describes the setup of sampling-based high voltage measuring systems for reactive compensation components recently developed at VTT and PTB. First measurements show an agreement within 10-4 between both measuring systems. Both a phantom power source emulating reactors and capacitors with adjustable losses, and a set of real reactive components were measured. Measurements were performed with stable 53 Hz frequency and variable 50 Hz power frequency. The measuring systems are developed within the frame of the European project "ELPOW-Metrology for the Electrical Power Industry".
    Original languageEnglish
    Title of host publicationPrecision Electromagnetic Measurements (CPEM 2016), 2016 Conference on
    PublisherIEEE Institute of Electrical and Electronic Engineers
    Pages1-3
    ISBN (Electronic)978-1-4673-9134-4, 978-1-4673-9132-0
    ISBN (Print)978-1-4673-9135-1
    DOIs
    Publication statusPublished - 11 Aug 2016
    MoE publication typeA4 Article in a conference publication
    EventConference on Precision Electromagnetic Measurements, CPEM 2016 - Ottawa, Canada
    Duration: 10 Jul 201615 Jul 2016

    Conference

    ConferenceConference on Precision Electromagnetic Measurements, CPEM 2016
    Abbreviated titleCPEM 2016
    Country/TerritoryCanada
    CityOttawa
    Period10/07/1615/07/16

    Keywords

    • Capacitor Losses
    • Loss compensation
    • Power Measurements
    • Precision Measurements
    • Reactor losses
    • Uncertainty