Results from international comparisons at the BIPM providing a world-wide reference network of 127/I/sub 2/ stabilized frequency-doubled Nd

YAG lasers

S. Picard, L. Robertsson, L.-S. Ma, Y. Millerioux, P. Juncar, J.-P. Wallerand, P. Balling, P. Kren, K. Nyholm, M. Merimaa, T.E. Ahola, F.-L. Hong

Research output: Contribution to journalArticleScientificpeer-review

14 Citations (Scopus)

Abstract

Frequency comparisons have been carried out between iodine-stabilized Nd:YAG lasers from the Bureau International des Poids et Mesures, the Bureau National de Metrologie-Institut National de Metrologie, the Czech Metrology Institute, the Centre for Metrology and Accreditation, and the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology. The comparison data of these lasers can now be linked to the results of recent absolute frequency measurements of lasers from different institutes.
Original languageEnglish
Pages (from-to)236-239
Number of pages4
JournalIEEE Transactions on Instrumentation and Measurement
Volume52
Issue number2
DOIs
Publication statusPublished - 2003
MoE publication typeA1 Journal article-refereed

Fingerprint

metrology
YAG lasers
Lasers
frequency measurement
iodine
lasers
Accreditation
Japan
Iodine

Cite this

Picard, S. ; Robertsson, L. ; Ma, L.-S. ; Millerioux, Y. ; Juncar, P. ; Wallerand, J.-P. ; Balling, P. ; Kren, P. ; Nyholm, K. ; Merimaa, M. ; Ahola, T.E. ; Hong, F.-L. / Results from international comparisons at the BIPM providing a world-wide reference network of 127/I/sub 2/ stabilized frequency-doubled Nd : YAG lasers. In: IEEE Transactions on Instrumentation and Measurement. 2003 ; Vol. 52, No. 2. pp. 236-239.
@article{22cfbf939e7a45668019eb4980e0a031,
title = "Results from international comparisons at the BIPM providing a world-wide reference network of 127/I/sub 2/ stabilized frequency-doubled Nd: YAG lasers",
abstract = "Frequency comparisons have been carried out between iodine-stabilized Nd:YAG lasers from the Bureau International des Poids et Mesures, the Bureau National de Metrologie-Institut National de Metrologie, the Czech Metrology Institute, the Centre for Metrology and Accreditation, and the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology. The comparison data of these lasers can now be linked to the results of recent absolute frequency measurements of lasers from different institutes.",
author = "S. Picard and L. Robertsson and L.-S. Ma and Y. Millerioux and P. Juncar and J.-P. Wallerand and P. Balling and P. Kren and K. Nyholm and M. Merimaa and T.E. Ahola and F.-L. Hong",
year = "2003",
doi = "10.1109/TIM.2003.810459",
language = "English",
volume = "52",
pages = "236--239",
journal = "IEEE Transactions on Instrumentation and Measurement",
issn = "0018-9456",
publisher = "Institute of Electrical and Electronic Engineers IEEE",
number = "2",

}

Results from international comparisons at the BIPM providing a world-wide reference network of 127/I/sub 2/ stabilized frequency-doubled Nd : YAG lasers. / Picard, S.; Robertsson, L.; Ma, L.-S.; Millerioux, Y.; Juncar, P.; Wallerand, J.-P.; Balling, P.; Kren, P.; Nyholm, K.; Merimaa, M.; Ahola, T.E.; Hong, F.-L.

In: IEEE Transactions on Instrumentation and Measurement, Vol. 52, No. 2, 2003, p. 236-239.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - Results from international comparisons at the BIPM providing a world-wide reference network of 127/I/sub 2/ stabilized frequency-doubled Nd

T2 - YAG lasers

AU - Picard, S.

AU - Robertsson, L.

AU - Ma, L.-S.

AU - Millerioux, Y.

AU - Juncar, P.

AU - Wallerand, J.-P.

AU - Balling, P.

AU - Kren, P.

AU - Nyholm, K.

AU - Merimaa, M.

AU - Ahola, T.E.

AU - Hong, F.-L.

PY - 2003

Y1 - 2003

N2 - Frequency comparisons have been carried out between iodine-stabilized Nd:YAG lasers from the Bureau International des Poids et Mesures, the Bureau National de Metrologie-Institut National de Metrologie, the Czech Metrology Institute, the Centre for Metrology and Accreditation, and the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology. The comparison data of these lasers can now be linked to the results of recent absolute frequency measurements of lasers from different institutes.

AB - Frequency comparisons have been carried out between iodine-stabilized Nd:YAG lasers from the Bureau International des Poids et Mesures, the Bureau National de Metrologie-Institut National de Metrologie, the Czech Metrology Institute, the Centre for Metrology and Accreditation, and the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology. The comparison data of these lasers can now be linked to the results of recent absolute frequency measurements of lasers from different institutes.

U2 - 10.1109/TIM.2003.810459

DO - 10.1109/TIM.2003.810459

M3 - Article

VL - 52

SP - 236

EP - 239

JO - IEEE Transactions on Instrumentation and Measurement

JF - IEEE Transactions on Instrumentation and Measurement

SN - 0018-9456

IS - 2

ER -