Round Robin test on heat exchanger for district heating

    Research output: Book/ReportReport

    Abstract

    Four partners from three Nordic countries carried out for the first time a Round Robin test on a heat exchanger designed for district heating applications.
    The aim was to investigate the level of uncertainty achieved in determining the thermal capacity and pressure losses in a heat exchanger.Project results will be used to improve quality procedures in participating laboratories and also can serve as a reference when revision of relevant CEN standard will be activated. Since the standard may be used in type testing of exchangers prior to their admission to the market, quality of testing has its own meaning in sustaining and upgrading the technical quality of district heating, a major Nordic heating technology.
    Original languageEnglish
    PublisherVTT Technical Research Centre of Finland
    Number of pages20
    Publication statusPublished - 2003
    MoE publication typeD4 Published development or research report or study

    Publication series

    SeriesNordtest technical report
    Number532
    ISSN0283-7234
    SeriesVTT Rakennustekniikka. Tutkimusraportti
    NumberRTE1267/03

    Fingerprint

    District heating
    Heat exchangers
    Testing
    Specific heat
    Heating
    Uncertainty

    Cite this

    Klobut, K. (2003). Round Robin test on heat exchanger for district heating. VTT Technical Research Centre of Finland. Nordtest technical report, No. 532, VTT Rakennustekniikka. Tutkimusraportti, No. RTE1267/03
    Klobut, Krzysztof. / Round Robin test on heat exchanger for district heating. VTT Technical Research Centre of Finland, 2003. 20 p. (Nordtest technical report; No. 532). (VTT Rakennustekniikka. Tutkimusraportti; No. RTE1267/03).
    @book{282407967c3f4ab8bad9b11cb93b41d1,
    title = "Round Robin test on heat exchanger for district heating",
    abstract = "Four partners from three Nordic countries carried out for the first time a Round Robin test on a heat exchanger designed for district heating applications.The aim was to investigate the level of uncertainty achieved in determining the thermal capacity and pressure losses in a heat exchanger.Project results will be used to improve quality procedures in participating laboratories and also can serve as a reference when revision of relevant CEN standard will be activated. Since the standard may be used in type testing of exchangers prior to their admission to the market, quality of testing has its own meaning in sustaining and upgrading the technical quality of district heating, a major Nordic heating technology.",
    author = "Krzysztof Klobut",
    year = "2003",
    language = "English",
    series = "Nordtest technical report",
    number = "532",
    publisher = "VTT Technical Research Centre of Finland",
    address = "Finland",

    }

    Klobut, K 2003, Round Robin test on heat exchanger for district heating. Nordtest technical report, no. 532, VTT Rakennustekniikka. Tutkimusraportti, no. RTE1267/03, VTT Technical Research Centre of Finland.

    Round Robin test on heat exchanger for district heating. / Klobut, Krzysztof.

    VTT Technical Research Centre of Finland, 2003. 20 p. (Nordtest technical report; No. 532). (VTT Rakennustekniikka. Tutkimusraportti; No. RTE1267/03).

    Research output: Book/ReportReport

    TY - BOOK

    T1 - Round Robin test on heat exchanger for district heating

    AU - Klobut, Krzysztof

    PY - 2003

    Y1 - 2003

    N2 - Four partners from three Nordic countries carried out for the first time a Round Robin test on a heat exchanger designed for district heating applications.The aim was to investigate the level of uncertainty achieved in determining the thermal capacity and pressure losses in a heat exchanger.Project results will be used to improve quality procedures in participating laboratories and also can serve as a reference when revision of relevant CEN standard will be activated. Since the standard may be used in type testing of exchangers prior to their admission to the market, quality of testing has its own meaning in sustaining and upgrading the technical quality of district heating, a major Nordic heating technology.

    AB - Four partners from three Nordic countries carried out for the first time a Round Robin test on a heat exchanger designed for district heating applications.The aim was to investigate the level of uncertainty achieved in determining the thermal capacity and pressure losses in a heat exchanger.Project results will be used to improve quality procedures in participating laboratories and also can serve as a reference when revision of relevant CEN standard will be activated. Since the standard may be used in type testing of exchangers prior to their admission to the market, quality of testing has its own meaning in sustaining and upgrading the technical quality of district heating, a major Nordic heating technology.

    M3 - Report

    T3 - Nordtest technical report

    BT - Round Robin test on heat exchanger for district heating

    PB - VTT Technical Research Centre of Finland

    ER -

    Klobut K. Round Robin test on heat exchanger for district heating. VTT Technical Research Centre of Finland, 2003. 20 p. (Nordtest technical report; No. 532). (VTT Rakennustekniikka. Tutkimusraportti; No. RTE1267/03).