The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method: version 2

Petri Österberg, Martti Heinonen, Maija Ojanen-Saloranta, Anssi J. Mäkynen

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

1 Citation (Scopus)

Abstract

This article compares the performance of a microwave based moisture measurement instrument against the conventional moisture measurement reference method Loss-on-Drying (LoD). Six different biomaterials were measured at three moisture content levels with both measurement methods. After instrument calibrations, the difference and variation of the measurement results and the repeatability of the instruments for parallel samples were estimated. Good agreement between the measurement methods was achieved with careful microwave instrument calibration.
Original languageEnglish
Title of host publication21st IMEKO World Congress 2015
Subtitle of host publicationMeasurement in Research and Industry
Number of pages6
Publication statusPublished - 2015
MoE publication typeA4 Article in a conference publication
Event21st IMEKO World Congress 2015: Measurement in Research and Industry - Prague, Czech Republic
Duration: 30 Aug 20154 Sep 2015
Conference number: 21

Conference

Conference21st IMEKO World Congress 2015
CountryCzech Republic
CityPrague
Period30/08/154/09/15

Fingerprint

bioenergy
measurement method
results measurement
performance

Keywords

  • bioenergy
  • LoD
  • microwave
  • moisture measurement
  • oven drying

Cite this

Österberg, P., Heinonen, M., Ojanen-Saloranta, M., & Mäkynen, A. J. (2015). The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method: version 2. In 21st IMEKO World Congress 2015: Measurement in Research and Industry
Österberg, Petri ; Heinonen, Martti ; Ojanen-Saloranta, Maija ; Mäkynen, Anssi J. / The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method : version 2. 21st IMEKO World Congress 2015: Measurement in Research and Industry. 2015.
@inproceedings{69b89f679833493da5f97d884dee3cec,
title = "The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method: version 2",
abstract = "This article compares the performance of a microwave based moisture measurement instrument against the conventional moisture measurement reference method Loss-on-Drying (LoD). Six different biomaterials were measured at three moisture content levels with both measurement methods. After instrument calibrations, the difference and variation of the measurement results and the repeatability of the instruments for parallel samples were estimated. Good agreement between the measurement methods was achieved with careful microwave instrument calibration.",
keywords = "bioenergy, LoD, microwave, moisture measurement, oven drying",
author = "Petri {\"O}sterberg and Martti Heinonen and Maija Ojanen-Saloranta and M{\"a}kynen, {Anssi J.}",
year = "2015",
language = "English",
isbn = "9781510812925",
booktitle = "21st IMEKO World Congress 2015",

}

Österberg, P, Heinonen, M, Ojanen-Saloranta, M & Mäkynen, AJ 2015, The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method: version 2. in 21st IMEKO World Congress 2015: Measurement in Research and Industry. 21st IMEKO World Congress 2015, Prague, Czech Republic, 30/08/15.

The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method : version 2. / Österberg, Petri; Heinonen, Martti; Ojanen-Saloranta, Maija; Mäkynen, Anssi J.

21st IMEKO World Congress 2015: Measurement in Research and Industry. 2015.

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

TY - GEN

T1 - The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method

T2 - version 2

AU - Österberg, Petri

AU - Heinonen, Martti

AU - Ojanen-Saloranta, Maija

AU - Mäkynen, Anssi J.

PY - 2015

Y1 - 2015

N2 - This article compares the performance of a microwave based moisture measurement instrument against the conventional moisture measurement reference method Loss-on-Drying (LoD). Six different biomaterials were measured at three moisture content levels with both measurement methods. After instrument calibrations, the difference and variation of the measurement results and the repeatability of the instruments for parallel samples were estimated. Good agreement between the measurement methods was achieved with careful microwave instrument calibration.

AB - This article compares the performance of a microwave based moisture measurement instrument against the conventional moisture measurement reference method Loss-on-Drying (LoD). Six different biomaterials were measured at three moisture content levels with both measurement methods. After instrument calibrations, the difference and variation of the measurement results and the repeatability of the instruments for parallel samples were estimated. Good agreement between the measurement methods was achieved with careful microwave instrument calibration.

KW - bioenergy

KW - LoD

KW - microwave

KW - moisture measurement

KW - oven drying

M3 - Conference article in proceedings

SN - 9781510812925

BT - 21st IMEKO World Congress 2015

ER -

Österberg P, Heinonen M, Ojanen-Saloranta M, Mäkynen AJ. The comparison of a microwave based bioenergy moisture measurement instrument against the Loss-On-Drying method: version 2. In 21st IMEKO World Congress 2015: Measurement in Research and Industry. 2015